phases are connected, as the line voltage phases must match the current phases
for accurate power measurement.
Connecting data
communication
cables to invert-
ers
Fronius SnapINveter:
Connect the data communication ports of the Fronius Smart Meter to the Froni-
us system monitoring in the inverter. Several Smart Meters can be installed in the
system, see chapter
Multi meter system - Fronius SnapINverter
1
Connect
D-
to
D-
.
2
Connect
D+
to
D+
.
3
Connect
-
to
-
.
Fronius GEN24 inverter:
Connect the data communication ports of the Fronius Smart Meter to the Mod-
bus interface of the Fronius GEN24 inverter. Several Smart Meters can be in-
stalled in the system, see chapter
Multi meter system - Fronius GEN24 inverter
on page
1
Connect
D-
to
M1-
.
2
Connect
D+
to
M1+
.
3
Connect
-
to
GND
.
14
Содержание WND-WR-MB
Страница 2: ......
Страница 12: ...Three Phase Four Wire Wye Three Phase Three Wire Delta without Neutral Three Phase Four Wire Stinger 12 ...
Страница 17: ...17 EN US ...
Страница 23: ...Commissioning 23 ...
Страница 24: ...24 ...
Страница 29: ...The Fronius Smart Meter is configured as a secondary meter 29 EN US ...
Страница 35: ...35 EN US ...
Страница 36: ... ...