IMPORTANT!
Under certain circumstances, it may not be possible to change
welding parameters that have been set on the control panel of a system compon-
ent - such as remote control or wirefeeder - on the control panel of the power
source.
3
Press the "Parameter selection" button to select the wire speed parameter
4
Use the selection dial to set the desired wire speed value
5
Press the "Parameter selection" button to select the welding voltage para-
meter
6
Use the selection dial to set the desired welding voltage value
The welding parameter values are shown in the digital display located above.
All welding parameter set values remain stored until the next time they are
changed. This applies even if the power source is switched off and on again. To
display the actual welding current during welding, select the welding current
parameter.
To display the actual welding current during welding:
-
Press the "Parameter selection" button to select the welding current para-
meter
-
The actual welding current is shown on the digital display during welding.
7
Open the gas cylinder valve
8
Adjust quantity of shielding gas:
-
Tap the Gas-test button
-
Turn the adjusting screw on the bottom of the gas pressure regulator un-
til the manometer displays the desired quantity of gas
-
Tap the Gas-test button again
CAUTION!
Danger of injury and damage from electric shock and from the wire electrode
emerging from the torch.
When you press the torch trigger:
▶
Keep the welding torch away from your face and body
▶
Wear suitable protective goggles
▶
Do not point the welding torch at people
▶
Make sure that the wire electrode does not touch any conductive or groun-
ded parts (e.g., housing, etc.)
9
Press the torch trigger and start welding
Corrections dur-
ing welding
To obtain the best possible welding results, the arc-force dynamic parameter will
sometimes need to be adjusted.
1
Press the "Parameter selection" button to select the arc-force dynamic para-
meter
2
Use the selection dial to set the desired arc-force dynamic value
The welding parameter value is shown in the digital display located above it.
73
EN-US
Содержание TransSteel 4000 Pulse
Страница 2: ......
Страница 18: ...18...
Страница 19: ...General information 19...
Страница 20: ...20...
Страница 29: ...Operating controls and connec tions 29...
Страница 30: ...30...
Страница 40: ...40...
Страница 41: ...Installation and Startup 41...
Страница 42: ...42...
Страница 59: ...MIG MAG welding 59...
Страница 60: ...60...
Страница 79: ...MMA welding arc air gouging 79...
Страница 80: ...80...
Страница 87: ...Easy Documentation 87...
Страница 88: ...88...
Страница 93: ...Setup Settings 93...
Страница 94: ...94...
Страница 109: ...Troubleshooting and Maintenance 109...
Страница 110: ...110...
Страница 120: ...120...
Страница 121: ...Appendix 121...
Страница 122: ...122...
Страница 139: ...139 EN US...
Страница 140: ......