102
to7 | xxx
Note: xxx stands for a temperature value
Cause:
Overtemperature in the power source
Remedy:
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
toF | xxx
Cause:
With the TSt 2500c MV / TSt 2700c MV power source operating in single-
phase mode, the power source safety cut-out has tripped in order to prevent
the mains fuse from tripping.
Remedy:
After a pause in welding of around 60 s, the message disappears and the
power source is operational again.
tu0 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the power source primary circuit
Remedy:
Place power source in a heated room and allow to warm up
tu1 | xxx
Note: xxx stands for a temperature value
Cause:
Undertemperature on the booster located in the power source
Remedy:
Place power source in a heated room and allow it to warm up
tu2 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the power source secondary circuit
Remedy:
Place power source in a heated room and allow to warm up
tu3 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the wire-feed unit motor
Remedy:
Place wire-feed unit in a heated room and allow to warm up
tu4 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the welding torch
Remedy:
Place welding torch in a heated room and allow to warm up
tu5 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the cooling unit
Remedy:
Place cooling unit in a heated room and allow to warm up
tu6 | xxx
Note: xxx stands for a temperature value
Cause:
Undertemperature on the transformer of the power source
Remedy:
Place power source in a heated room and allow it to warm up
Содержание TransSteel 2500c
Страница 2: ...2...
Страница 4: ...4...
Страница 8: ...8...
Страница 20: ...20...
Страница 21: ...General information...
Страница 22: ......
Страница 29: ...Control elements and connections...
Страница 30: ......
Страница 39: ...Installation and commissioning...
Страница 40: ......
Страница 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Страница 63: ...Welding...
Страница 64: ......
Страница 77: ...77 EN Number 3 Number 4 Number 5...
Страница 78: ...78...
Страница 79: ...Setup settings...
Страница 80: ......
Страница 93: ...Troubleshooting and maintenance...
Страница 94: ......
Страница 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...