73
EN
Press "Finish"
(or press the adjusting dial)
Process parame-
ters for compo-
nents
The following process parameters can be set and displayed for the system components of
a welding device:
10
Values:
R = 1,3 mOhm (before: 1,7 mOhm)
L = 5,0 µH (before: 4,0 µH )
> The R/L adjustment has been performed successfully.
To finish the wizard press “Finish“ .
AlMg 5
10
Cooling unit mode
to determine whether a cooling unit is to be switched on or off, or operated automatically
Setting range
eco / auto / on / off (depending on the cooling unit)
Factory setting
auto
Flow watchdog filter time
for setting the time from when the flow watchdog responds until a warning message is
output
Unit
s
Setting range
5 - 25
Factory setting
5
Feeder inching speed
for setting the wire feed speed at which the wire electrode is threaded into the torch
hosepack
Unit
m/min
Setting range
min. - max.
Factory setting
-
Содержание TPS 320i
Страница 2: ...0 ...
Страница 4: ...2 ...
Страница 8: ...6 ...
Страница 21: ...General information ...
Страница 22: ......
Страница 27: ...Controls connections and mechani cal components ...
Страница 28: ......
Страница 32: ...30 ...
Страница 33: ...Operating concept ...
Страница 34: ......
Страница 39: ...Installation and commissioning ...
Страница 40: ......
Страница 45: ...43 EN 3 4 5 3 4 5 9 8 7 6 2 6 ...
Страница 51: ...Welding ...
Страница 52: ......
Страница 76: ...74 ...
Страница 77: ...Defaults ...
Страница 78: ......
Страница 81: ...Troubleshooting and maintenance ...
Страница 82: ......
Страница 87: ...Appendix ...
Страница 88: ......