70
Process parame-
ters for process
regulation
The following parameters can be set and displayed for the process control:
R/L adjustment
Align the welding circuit resistance (R) and welding circuit inductivity (L) if one of the fol-
lowing components of the welding device is changed:
-
Torch hosepacks
-
Interconnecting hosepacks
-
Grounding (earthing) cables, welding cables
-
Wire-feed units
-
Welding torches, electrode holders
-
Push-pull units
Prerequisites for R/L adjustment
The welding system must be complete: closed welding loop with torch and torch hosepack,
wire-feed units, grounding (earthing) cable, interconnecting hosepacks.
Performing R/L adjustment
Select the "Process parameters" button in the left-hand ribbon
Setting range
0 - 9.9
Factory setting
0.5
Fusion penetration stabiliser
for setting the max. permitted change in the wire feed speed, so as to keep the fusion pen-
etration stable or constant with variable stickout
The fusion penetration stabiliser parameter is only available when the option WP PMC
(Welding Process Puls Multi Control) or WP LSC (Welding Process Low Spatter Control)
has been enabled on the power source.
Unit
m/min
Setting range
off / 0; 0.1 - 10.0
Factory setting
off / 0
1
R/L adjustment
2
AlMg 5
1
Содержание TPS 320i
Страница 2: ...0 ...
Страница 4: ...2 ...
Страница 8: ...6 ...
Страница 21: ...General information ...
Страница 22: ......
Страница 27: ...Controls connections and mechani cal components ...
Страница 28: ......
Страница 32: ...30 ...
Страница 33: ...Operating concept ...
Страница 34: ......
Страница 39: ...Installation and commissioning ...
Страница 40: ......
Страница 45: ...43 EN 3 4 5 3 4 5 9 8 7 6 2 6 ...
Страница 51: ...Welding ...
Страница 52: ......
Страница 76: ...74 ...
Страница 77: ...Defaults ...
Страница 78: ......
Страница 81: ...Troubleshooting and maintenance ...
Страница 82: ......
Страница 87: ...Appendix ...
Страница 88: ......