Max. switchable inductive loads at digital
outputs
76 mJ
(per output)
Modbus RTU
RS485 2 wire
Factory settings for RS485 interface:
Speed
Data frames
9600 baud
1 start bit
8 Data bits
No parity
1 stop bit
Explanation of
footnotes
1)
The values stated are defaults; the inverter is configured specifically to suit the
requirements of the relevant country.
2)
Depending on the country setup or device-specific settings
(ind. = inductive; cap. = capacitive)
3)
PCC = interface to the public grid
4)
Maximum current from the inverter to the solar module when an error occurs in
the inverter
5)
Guaranteed by the electrical configuration of the inverter
6)
Current peak when switching on the inverter
Applicable stand-
ards and
guidelines
Fronius hybrid inverter:
CE mark
The devices conform to all the requisite and relevant standards and guidelines that form
part of the relevant EU directive, and are therefore permitted to display the CE mark.
Emergency power operation
This version of the hybrid inverter is only intended for use in grid connected photovoltaic
systems. A device update is required from the manufacturer in order to generate power
independently of the public grid. As well as providing functional enhancements for the
hardware and software, this update also includes relevant user documentation.
The hybrid inverter is delivered ready for supplying emergency power.
Power outage
The standard measurement and safety procedures integrated into the inverter ensure
that in the event of a power outage, the feed-in of energy is immediately interrupted (e.g.
switch-off by the energy supplier or damage to lines).
Fronius Solar Battery:
-
IEC/EN 62133
-
EN 50178 (1997)
-
EN 61000-6-2:2005
-
EN 61000-6-3:2007 + A1:2011
-
EN 62208
-
EN 62311:2008
-
FCC Part 15 Subpart B:2012 Class B
-
IEC 60730-1 (Fourth Edition) 2010 (H.7, H.11.12, H.27.1.2)
-
UN 38.3
-
60730-1 2011 (H.7, H.11.12, H.27.1.2)
138
Содержание Symo Hybrid 3.0-3-S
Страница 2: ......
Страница 10: ...10 ...
Страница 11: ...General information 11 ...
Страница 12: ...12 ...
Страница 16: ...16 ...
Страница 34: ...34 ...
Страница 35: ...Operation 35 ...
Страница 36: ...36 ...
Страница 66: ...66 ...
Страница 67: ...Fronius system monitoring 67 ...
Страница 68: ...68 ...
Страница 80: ...80 ...
Страница 81: ...Current data services and settings offered by Fronius system monitor ing 81 ...
Страница 82: ...82 ...
Страница 119: ...Troubleshooting and maintenance 119 ...
Страница 120: ...120 ...
Страница 133: ...Appendix 133 ...
Страница 134: ...134 ...