HYBRID
P
AC nom
=
5 kW
P
AC nom
=
7 kW
P
AC nom
>
P
AC nom
(inverter 1) > P
AC nom
(hybrid)
Example: 7 kW > 5 kW
Two Smart Meters are required for the
inverters. These must be installed at the
feed-in point.
Hybrid system overview (web page):
Settings – System overview: Meter must
be configured at the feed-in point
Datamanager overview (web page):
Settings – System overview: Meter must
be configured at the feed-in point
Settings – PSC editor:
Dynamic power reduction
Power limit: Limit for the entire system
Total DC system output: 12,000 Wp
Max. grid power feed: 60%
117