After transporting the device, it must be visually inspected for damage before
commissioning. Any damage must be repaired by trained service technicians be-
fore commissioning the device.
Safety measures
in normal opera-
tion
Only operate the device if all safety devices are fully functional. If the safety
devices are not fully functional, there is a risk of
-
injury or death to the operator or a third party,
-
damage to the device and other material assets belonging to the operator,
-
inefficient operation of the device.
Any safety devices that are not functioning properly must be repaired before
switching on the device.
Never bypass or disable safety devices.
Before switching on the device, ensure that no one is likely to be endangered.
Check the device at least once a week for obvious damage and proper function-
ing of safety devices.
-
Only use suitable original parting agent from the manufacturer.
-
Observe the information on the parting agent safety data sheet when hand-
ling parting agent. The parting agent safety data sheet may be obtained from
your service centre or downloaded from the manufacturer's website.
-
Do not mix the manufacturer's parting agent with other parting agents.
-
If damage results from using a different parting agent, the manufacturer ac-
cepts no liability. In addition, no warranty claims will be entertained.
-
Used parting agent must be disposed of properly in accordance with the rel-
evant national and international regulations.
Commissioning,
maintenance and
repair
It is impossible to guarantee that bought-in parts are designed and manufac-
tured to meet the demands made of them, or that they satisfy safety require-
ments.
-
Use only original spare and wearing parts (also applies to standard parts).
-
Do not carry out any modifications, alterations, etc. to the device without the
manufacturer's consent.
-
Components that are not in perfect condition must be replaced immediately.
-
When ordering, please give the exact designation and part number as shown
in the spare parts list, as well as the serial number of your device.
The housing screws provide the ground conductor connection for earthing the
housing parts.
Only use original housing screws in the correct number and tightened to the spe-
cified torque.
Safety inspec-
tion
The manufacturer recommends that a safety inspection of the device is per-
formed at least once every 12 months.
A safety inspection should be carried out by a qualified electrician
-
after any changes are made
-
after any additional parts are installed, or after any conversions
-
after repair, care and maintenance has been carried out
-
at least every twelve months.
For safety inspections, follow the appropriate national and international stand-
ards and directives.
10
Содержание Robacta Reamer Alu 3000upm
Страница 2: ......
Страница 12: ...12...
Страница 13: ...General 13...
Страница 14: ...14...
Страница 23: ...Controls connections and mechan ical components 23...
Страница 24: ...24...
Страница 30: ...30...
Страница 31: ...Installation and commissioning 31...
Страница 32: ...32...
Страница 40: ...Attach the spatter tray retainer as shown 3 40...
Страница 67: ...Care maintenance and disposal 67...
Страница 68: ...68...
Страница 73: ...Troubleshooting 73...
Страница 74: ...74...
Страница 80: ...80...
Страница 81: ...Technical data 81...
Страница 82: ...82...
Страница 85: ...Appendix 85...
Страница 86: ...86...
Страница 87: ...Circuit diagram Robacta Reamer Robacta Ream er Alu Edition Robacta Reamer Alu Edition 3000rpm 87 EN...