125
Technical data
Fronius IG TL 3.0
Input data
Output data
General data
Maximum DC power
3130 W
MPP voltage range
350 - 700 V DC
Max. input voltage
(at 1000 W/m² / -10 °C in an open circuit)
850 V DC
Max. input current
8.8 A DC
Max. array short circuit current
13.2 A
Nominal output power (P
nom
)
3.0 kW
Max. output power
1)
3.0 kW
Nominal AC output voltage
2)
1 ~ NPE 230 V
Grid voltage range
2)
180 - 270 V
Maximum output current (single phase)
13 A AC
Nominal frequency
2)
50 - 60 Hz
1)
Harmonic distortion
< 3 %
Power factor (cos phi)
1
Max. permitted grid impedance Zmax at PCC
3)
None
Max. recovery current
4)
0 A
5)
Switch-on current pulses
6
)
0 A
5)
Maximum output fault current / duration
113 A / 89.5 µs
MPP adjustment efficiency
99,9 %
Maximum efficiency
97,7 %
Euro. efficiency
97,1 %
Night consumption
0.2 W
Cooling
Controlled forced-air ventila-
tion
Degree of protection
IP 55
in Australia, IP 45
Dimensions l x w x h
195 x 413 x 597 mm
Weight
19.1 kg
Permissible ambient temperature
(with 95% rel. humidity)
- 20 °C - +55 ?
EMC emissions class
B
Inverter concept
Transformerless
Degree of pollution
3
Over-voltage category (OVC)
AC 3 / DC 2
Protection class as per IEC 62103
1
Содержание IG-TL 3.0
Страница 2: ...0...
Страница 4: ...2...
Страница 14: ...12...
Страница 15: ...General Information...
Страница 16: ......
Страница 23: ...Installation and Startup...
Страница 24: ......
Страница 58: ...56...
Страница 59: ...Operation...
Страница 60: ......
Страница 97: ...Troubleshooting and Maintenance...
Страница 98: ......
Страница 119: ...117 Tightening torque 2 Nm 2 1 5 1 1 1 1 1 1 2 6 1 3 2 ON 7...
Страница 124: ...122...
Страница 125: ...Appendix...
Страница 126: ......
Страница 137: ...135...
Страница 138: ...136...
Страница 139: ...137...