102
Description
The inverter disconnects from the grid for safety reasons and
then attempts a restart.
Remedy
If status code persists: Contact a Fronius-trained service tech-
nician.
426
The intermediate circuit charging takes too long
Description
Short interruption of grid feed-in mode.
The inverter returns to the Startup phase.
Remedy
The fault is rectified automatically.
If this status code keeps recurring, contact your system install-
er.
427
Power stage set inoperative for too long (timeout)
Description
Short interruption of grid feed-in mode.
The inverter returns to the Startup phase.
Remedy
The fault is rectified automatically.
If this status code keeps recurring, contact your system install-
er.
428
Timeout error during connection
Description
Short interruption of grid feed-in mode.
The inverter returns to the Startup phase.
Remedy
If this status code keeps recurring, contact your system install-
er.
429
Timeout error when disconnecting
Description
Short interruption of grid feed-in mode.
The inverter returns to the Startup phase.
Remedy
If this status code keeps recurring, contact your system install-
er.
431
Power stage set software being updated
Description
Inverter does not feed energy into the grid.
Remedy
Update firmware using Fronius Solar.update or a USB stick
432
Internal database error during power stage set allocation
Description
The inverter disconnects from the grid for safety reasons and
then attempts a restart.
Содержание IG-TL 3.0
Страница 2: ...0...
Страница 4: ...2...
Страница 14: ...12...
Страница 15: ...General Information...
Страница 16: ......
Страница 23: ...Installation and Startup...
Страница 24: ......
Страница 58: ...56...
Страница 59: ...Operation...
Страница 60: ......
Страница 97: ...Troubleshooting and Maintenance...
Страница 98: ......
Страница 119: ...117 Tightening torque 2 Nm 2 1 5 1 1 1 1 1 1 2 6 1 3 2 ON 7...
Страница 124: ...122...
Страница 125: ...Appendix...
Страница 126: ......
Страница 137: ...135...
Страница 138: ...136...
Страница 139: ...137...