Mains connection
The equipment is designed to run on the mains voltage given on the respective rating
plates. If your version of the appliance does not come with the mains cables and plugs
ready-mounted, these must be mounted in accordance with your national regulations and
Standards. For details of fuse protection of the mains supply lead, please see the Techni-
cal Data.
Mains voltage of
FK 6000
FK 6000: fixed mains voltage
Setting the mains
voltage of FK
6000 Pipe
The FK 6000 Pipe cooling unit can be used with different mains voltages. The mains volt-
age set at the factory is shown on the rating plate.
FK 6000 Pipe: Setting the mains voltage
How to set the mains voltage:
Shift the mains switch into the “O” po-
sition
Unplug or otherwise disconnect the
unit from the mains power supply
Open the housing
Connect the phase conductor (L1) to
the appropriate terminal for your mains
voltage
Check that all cables are fixed firmly
Close the housing
Cross out the mains voltage originally
entered on the rating plate and - in the
empty box - enter the mains voltage
that you have just set
NOTE!
Inadequately dimensioned electrical installations can lead to serious
damage to (or loss of) property. The mains supply lead, and its fuse protection,
must be dimensioned accordingly. The technical data shown on the rating plate
shall apply.
CAUTION!
Running the unit on the wrong mains voltage can cause serious dam-
age. The mains voltage that you enter on the rating plate must be the same as
the voltage that you have just set.
IMPORTANT!
The FK 6000 cooling unit is
fixed at 230 V. It cannot be altered to any
other mains voltage.