44
The Basic menu
Accessing the
Basic menu
The Basic menu appears.
Use the "Plus" and "Minus" keys
to select the desired entry
Press the "Enter" key to open the desired menu item
Press the "Esc" key to exit the Basic menu
Menu items in the
Basic menu
Press the "Menu" key
The menu level appears.
Press the unassigned "Menu / Esc" key
5 times
"Access Code" is displayed in the "CODE" menu;
the first digit starts flashing.
Enter the code 22742: Use the "Plus" and
"Minus" keys
to select a value for the
first digit of the code
Press the "Enter" key
The second digit flashes.
Repeat steps 3 and 4 for the second, third,
fourth and fifth digits of the access code un
-
til...
the selected code starts flashing.
Press the "Enter" key
1
2
3
4
Access Code
5
6
7
8
9
The Basic menu is used to set the following parameters, which are important for installing
and operating the inverter:
MPP Tracker 1 / MPP Tracker 2
-
MPP Tracker 2: ON / OFF (MultiMPP Tracker devices only, excluding Fronius Symo
15.0-3 208)
-
DC operating mode: MPP AUTO / FIX / MPP USER
-
MPP AUTO: normal operating status; the inverter automatically searches for the
ideal operating point
-
FIX: for entering a fixed DC voltage at which the inverter will operate
-
MPP USER: for entering a lower MP voltage above which the inverter will search
for its ideal operating point
-
Dynamic Peak Manager: ON / OFF
-
Fixed voltage: for entering the fixed voltage
-
MPPT start voltage: for entering the start voltage