32
USB
Running firmware updates or saving detailed information from the inverter to the USB flash
drive
Safely remove hardware
To remove a USB flash drive from the USB A socket on the plug-in data communications
card without losing any data.
The USB flash drive can be removed:
-
If the OK message appears
-
when the "Data transfer" LED stops flashing or comes on steady
Software update
To update the inverter firmware using a USB flash drive.
Procedure:
Download the relevant firmware update file "froxxxxx.upd"
(e.g. from http://www.fronius.com; xxxxx stands for the version number)
NOTE!
To successfully update the inverter software, the USB flash drive provided for the
purpose must not have a hidden partition or any encryption (see chapter "Suitable
USB flash drives").
Save the firmware update file to the highest data level of the USB flash drive
Open the lid of the data communication area on the inverter
Plug the USB flash drive containing the firmware update file into the USB socket in the
inverter's data communication area
Select "USB" from the Setup menu, followed by "Software update"
Press the "Enter" key
Wait until the version currently installed on the inverter and the new firmware version
are displayed for comparison:
-
First page: Recerbo software (LCD), key controller software (KEY), country setup
version (Set)
-
Second page: Power stage set software (PS1/PS2)
Press the "Enter" function button after each page
The inverter starts copying the data.
"BOOT" and the progress of storing the individual tests expressed in % are displayed until
all the data for all the electronic modules has been copied.
Once copying is complete, the inverter updates the electronic modules as required in se
-
quence.
"BOOT", the affected modules and the update progress in % are displayed.
Factory setting
Fronius Solar Net
* The protocol type "Interface" only functions when there is no Datamanager card in the
inverter. All Fronius Datamanager cards should be removed from the inverter.
Setting range
Safely remove hardware / Software update / Logging interval
1
2
3
4
5
6
7
8
Содержание Eco 25.0-3-S
Страница 2: ...2...
Страница 64: ...64...
Страница 128: ...128 Sezionatore CC Integrata RCMU Integrata Fronius Symo 10 0 3 M 10 0 3 M OS 12 5 3 M...
Страница 195: ...195 PT BR...