34
Service Mes-
sages
(continued)
(7) Message to fax recipient
Activate to send service messages to a fax number
(8) Field to enter country code
e.g.: +43 = country code for Austria
(9) Field to enter the fax area code
(10) Field to enter the fax number
(11) Field for sending daily
(12) Selection field for the time when a service message will be sent via fax
(13) ‘Send test fax’ button
(14) Message to SMS recipient
Activate to send service messages as an SMS to a telephone number
(15) Field to enter country code
e.g.: +43 = country code for Austria
(16) Field to enter area code
(17) Field to enter the telephone number
(18) Field for sending daily
(19) Selection field for the time when a service message will be sent via SMS
(20) ‘Send test SMS’ button
Important
Check you settings by sending a test message.
(21) ‘Save’ button
(22) ‘Cancel’ button
(23) Relay and buzzer
For a direct warning onsite.
Along with the acoustical signal of the buzzer, additional warnings can also be
triggered via the relay output (e.g. signal horn, warning light, etc.).
The relay contact is a NCC (normally closed contact) and NOC (normally open
contact) and is designed for the following max. voltage/current values:
42 V AC / 6A
60 V DC / 400 mA
40 V DC / 1 A
30 V DC / 6 A
The buzzer and relay are activated or deactivated using the Alarm switch on the
Datalogger. An alarm is acknowledged by switching it briefly to ‘Alarm off.’
When ‘Alarm on’ is selected, the buzzer and relay are briefly activated as a test
function.
(24) ‘Run test’ button
Switches the relay and buzzer on for 1 second when the ‘Alarm on’ switch is set
Содержание Datalogger Web