7
Installing ‘Froni-
us Datalogger
Web’
Before Installing
Important
Please see the operating instructions for the inverter as well as the ‘Fronius
IG DATCOM Details’ section.
1.
Install ‘Fronius Datalogger Web’ in the
proper position using the screws and
assembly dowels provided in the
scope of delivery
2.
Insert the red Solar Net cable into the
Solar Net output (OUT) of the ‘Fronius
Com Card’
3.
If the ‘Fronius Com Card’ is the last
DATCOM component in the network:
Insert a terminating plug into the Solar
Net OUT connection
Fronius
Com Card
IN
OUT
CAUTION!
DATCOM components and/or the PC / laptop will be damaged if
the Ethernet or Solar Net cables are connected incorrectly.
-
The Ethernet cable should only be inserted into the LAN connection
(marked in blue)
-
The Solar Net cable should only be inserted into the Solar Net IN or Solar
Net OUT connections (marked in red)
Fronius Com Card
1.
Insert the red Solar Net cable into the Solar Net IN connection
2.
If the ‘Fronius Datalogger Web’ is the last DATCOM component in the network:
Insert a terminating plug into the Solar Net OUT connection
If there are additional DATCOM components in the network after the ‘Fronius
Datalogger Web’:
Insert an additional red Solar Net cable into the Solar Net OUT connection
3.
Insert the blue Ethernet cable into the LAN connection
4.
Insert the blue Ethernet cable into the PC/laptop or into a corresponding network
connection
Installing ‘Fronius Datalogger Web’
Содержание Datalogger Web
Страница 1: ...Fronius Datalogger Web 42 0426 0064 EA 012008 Operating Instructions GB Data Communication USA ...
Страница 2: ......
Страница 4: ...ud_fr_st_et_01382 012007 ...