CU 1100i /MV RVP
Mains voltage
200 - 230 V AC / 400 - 460 V AC
Mains voltage tolerance
-10% / +10%
Grid frequency
50/60 Hz
Current consumption
0.8 A / 0.35 A
Cooling power at
Q = 1 l/min + 25 °C (77 °F)
Q = 1 l/min + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
1100 W
800 W
1500 W
1100 W
Max. delivery head
45 m
147 ft. 7.65 in.
Max. delivery rate
2 l/min
0.53 gal./min [US]
Max. pump pressure
5 bar
72.52 psi
Pump
Vane pump
Pump service life
approx. 10,000 hrs
Coolant capacity
6 l
1.59 gal. [US]
Degree of protection
IP 23
Dimensions l/w/h
710/300/230 mm
27.95/11.81/9.06 in.
Weight (without coolant)
16.5 kg
39.68 Ib.
Flow monitoring
(sensor)
Warning between 1 and 0.7 l/min (0.26 -
0.18 gal./min [US]),
error message below 0.7 l/min (0.18
gal./min [US])
Coolant temperature monitoring
Warning above 68 °C (154.4 °F),
error message above 70 °C (158 °F)
Level sensor*
(functionality depends on the options in-
stalled in the device)
Warning or error message
Mark of conformity
CE, CSA
* Optional
79
EN
Содержание CU 1100i
Страница 2: ......
Страница 16: ...16...
Страница 17: ...General information 17...
Страница 18: ...18...
Страница 26: ...26...
Страница 27: ...Connections and mechanical com ponents 27...
Страница 28: ...28...
Страница 31: ...Installation and commissioning 31...
Страница 32: ...32...
Страница 45: ...Close the cover on the cooling unit connection 3 45 EN...
Страница 46: ...46...
Страница 47: ...Troubleshooting 47...
Страница 48: ...48...
Страница 53: ...Care maintenance and disposal 53...
Страница 54: ...54...
Страница 70: ...70...
Страница 71: ...Technical data 71...
Страница 72: ...72...
Страница 82: ...82...
Страница 83: ...83 EN...