![Fronius CU 1100i Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/fronius/cu-1100i/cu-1100i_operating-instructions-manual_2338988073.webp)
Technical data
General
The cooling capacity of a cooling unit depends on
-
Ambient temperature
-
Delivery head
-
Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
CU 800i,
CU 800i /460 V
CU 800i
Mains voltage
400 V AC
Mains voltage tolerance
-10% / +10%
Grid frequency
50/60 Hz
Current consumption
0.7 A
Cooling capacity at
Q=1 l/min. + 25 °C (77 °F)
Q = 1l / min. + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
800 W
500 W
1160 W
730 W
Max. delivery head
35 m
(114 ft. 9.95 in.)
Max. delivery rate
3.5 l/min
(0.92 gal./min [US])
Max. pump pressure
4.2 bar
(60.92 psi)
Pump
Centrifugal pump
Pump service life
approx. 10,000 hrs
Coolant capacity
4.5 l
(1.19 gal. [US])
Degree of protection
IP 23
Dimensions l/w/h
706/260/219 mm
(27.8/10.24/8.62 in.)
Weight (without coolant)
11.2 kg
(24.69 Ib.)
Flow monitoring*
(sensor)
Warning at 1 - 0.7 l/min
(0.26 - 0.18 gal./min [US])
Error message below 0.7 l/min
(0.18 gal./min [US])
Coolant temperature monitoring*
Warning above 68 °C (154.4 °F)
Error message above 70 °C (158 °F)
Mark of conformity
CE
* Optional
73
EN
Содержание CU 1100i
Страница 2: ......
Страница 16: ...16...
Страница 17: ...General information 17...
Страница 18: ...18...
Страница 26: ...26...
Страница 27: ...Connections and mechanical com ponents 27...
Страница 28: ...28...
Страница 31: ...Installation and commissioning 31...
Страница 32: ...32...
Страница 45: ...Close the cover on the cooling unit connection 3 45 EN...
Страница 46: ...46...
Страница 47: ...Troubleshooting 47...
Страница 48: ...48...
Страница 53: ...Care maintenance and disposal 53...
Страница 54: ...54...
Страница 70: ...70...
Страница 71: ...Technical data 71...
Страница 72: ...72...
Страница 82: ...82...
Страница 83: ...83 EN...