2
Rev.0 16/11/2021
Operator Panel | ROBOT - POST
2
1.1.1
CONTROLS DESCRIPTION
A
Programmed cycle START button.
B
Press and hold to lift the carriage manually.
C
Decrease values button.
D
Increase values button.
E
Alarm reset
(fast pressure – less than 2 second);
Saving parameters (press until the LED flashes - more than 3
seconds);
When pressed along with the
STOP
button, it stops and resets
the cycle (the display
(V)
shows
INI
to show the cancellation).
F
2-digit display indicating the functions (parameters) of the
selected programme;
During the cycle it shows the current operating status;
CF
on the display
(V)
at the end of the cycle means the film is
depleted;
AA
on the display
(V)
means there is an alarm on the machine.
G
Press and hold to lower the carriage manually.
H
STOP
button for cycle pause; the machine decelerates and stops;
the cycle can be resumed from the same point. The display
(V)
shows the battery charge if the pushbutton is pressed when
the machine is stopped. The LED flashes when the battery is in
reserve.
O EMERGENCY
push-button (or shutdown if the machine is at a
standstill).
P
2-digit display showing the selected programme;
During the cycle it shows an animation of the rotation;
NOTE
: the flashing display indicates that a parameter has been
changed).
V
3-digit display indicating the value of the displayed function;
During the cycle or manually moving the film carriage, it indicates
the current height;
The central and left points are decimal points for the values.
When the right point is lit, the
V+
and
V-
keys are blocked and
the parameter values cannot be changed.
»