Froling FHG Скачать руководство пользователя страница 52

Appendix 

 

Page 52 

B0600008_US 

 v

 

TARM BIOMASS’ LIMITED EXPRESS WARRANTY IS ONLY EXTENDED TO AND COVERS THE TARM USA 

PRODUCT’S END USER WHO OWNS THE BUILDING IN WHICH THE TARM USA PRODUCT IS 

INSTALLED, AND COVERS ONLY REPAIRS OR REPLACEMENTS RESULTING FROM DEFECTS IN 

MATERIALS AND WORKMANSHIP.THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE 

DESCRIPTION IN THIS LIMITED WARRANTY,

 

AND TLIMITED WARRANTY IS IN LIEU OF AND TO THE 

EXCEPTION OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, 

WARRANTIES OF MERCHANTABILITY OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.  

EXCEPT AS OTHERWISE PROVIDED BY THIS LIMITED WARRANTY, TARM BIOMASS TAKES NO 

RESPONSIBILITY FOR THE QUALITY OF TARM BIOMASS PRODUCTS OR THAT THE GOODS WILL BE 

FIT FOR ANY PARTICULAR PURPOSE FOR WHICH YOU MAY BE BUYING THESE GOODS.  UNDER NO 

CIRCUMSTANCES SHALL TARM USA BE SUBJECT TO INCIDENTAL, CONSEQUENTIAL, INDIRECT, 

SPECIAL, PUNITIVE, ENHANCED COMPENSATORY, OR CONTINGENT DAMAGES, WHETHER A CLAIM 

IS BASED ON CONTRACT, TORT, STRICT LIABILITY, OR ANY OTHER THEORY OF LAW, ALL SUCH 

DAMAGES AND CLAIMS BEING SPECIFICALLY DISCLAIMED. 

 

  
Tarm Biomass’ limited warranty is void if a Tarm Biomass product is installed by someone other than a qualified 

contractor whose principal occupation is the sale or installation of plumbing and heating equipment, or if the 

original purchaser fails to have the boiler serviced or inspected at least once every two years by an experienced 

and qualified service person.  Repairs or replacements under this limited warranty must be performed by your 

dealer or someone authorized by him.  You may be required to present this limited warranty to the dealer 

before any work is performed.  You must pay for any work performed that is not covered by this limited 

warranty or that is not authorized by the dealer.  Tarm Biomass’ limited warranty shall be construed under the 

laws of New Hampshire.  Any dispute arising out of this warranty shall be tried only in a court in the State of 

New Hampshire, including the United States District Court for the State of New Hampshire.  If any legal action 

is brought in connection with this limited warranty, the prevailing party shall be entitled to recover all 

reasonable expenses it incurs in the action, including its reasonable attorneys’ fees, from the nonprevailing 

party. 

  

TARM USA’S LIMITED WARRANTY EXPRESSLY EXCLUDES COVERAGE FOR THE FOLLOWING:

 

1. 

Ordinary wear and tear and repairs or replacements necessitated by normal use. 

2. 

Repairs or replacements arising from corrosion including, but not limited to, the effects of a corrosive 

water supply or corrosive by-products of combustion formed when a boiler is run during warm weather 

temperatures or under other conditions that do not permit the boiler to reach necessary operating 

temperatures on a frequent basis as described in the Owner’s Manual provided by Tarm Biomass. 

3. 

Repairs or replacements of fittings, motors, fuel units, oil and gas burners, any and all controls, relief or 

regulating valves, transformers, and accessories.  

4. 

Repairs or replacements to repair damage caused by (i) operation with inadequate draft, (ii) having 

installed a boiler model that is incorrectly sized for the application (too few or too many BTU’s under 

normal operating conditions) or that is otherwise inappropriate for the application, (iii) excessive boiler 

internal temperature from burning improper materials as fuel or operating the boiler without 

appropriate draft control (for example, burning the boiler too hot when the boiler is coming up to 

temperature from a cold start), or (iv) any similar use that violates or is not recommended in the 

Owner’s Manual provided by Tarm Biomass. 

5. 

The repair or replacement of any component furnished by any other manufacturer or damage caused by 

the functioning or malfunctioning of any such component. 

  

This warranty gives you specific legal rights.  You may also have other rights that vary from state to state.  This 

warranty shall not be construed as inconsistent with any federal, state, or municipal law, regulation, or code 

that was applicable to the original installation site on the date the Tarm Biomass product was installed.  
  
Questions regarding this warranty may be referred to:  
Tarm Biomass, 4 Britton Lane, Box 285, Lyme, NH 03768 U.S.A.  (603) 795-9100  

 

 

KEEP THIS INFORMATION FOR YOUR RECORDS:

 

Model:                                        ___   Place of Purchase:  _____________________________ _____ 

Serial Number:                              ______________________  InstallationDate:

___________________ 

Installer________________________________________________________________________ 

Содержание FHG

Страница 1: ...nch language manual may be obtained from Tarm Biomass by calling 800 782 9927 or by email request to info tarmusa com Operation and Service Manual Wood Fired Central Heating Boiler FHG Read and follow...

Страница 2: ...Update Date May 2014 Reprint date Nov 2014...

Страница 3: ...chapter 2 Units of Measurement Most hardware and fittings on the boiler are metric some plumbing fit tings are British Straight Thread In this manual the convention used for dimensions is that values...

Страница 4: ...iler does not carry an ASME stamp The instructions in this manual and in supporting documentation addi tional instructions diagrams and component information provided by Tarm Biomass must be followed...

Страница 5: ...2 4 Safety devices 20 2 4 1 Devices for Preventing the Boiler from overheating 20 Pressure Relief Valve 20 Overheat Thermostat Safety Temperature Limit Switch STL 21 Gravity Over heat Dump Loop 21 Ove...

Страница 6: ...tem 39 4 6 Menu Boiler 39 4 6 1 Status Displays for the Boiler 39 4 6 2 Temperature settings for the Boiler 39 4 7 Menu System 40 4 7 1 Current values 40 4 7 2 Error 40 4 7 3 Basic Display parameters...

Страница 7: ...wer supply 46 6 2 Excessive temperature 46 6 3 Error messages at Boiler Control System 47 6 3 1 Acknowledging a error message 48 6 3 2 List of possible error message 48 6 4 Misoperation of Door Switch...

Страница 8: ...ontrol System Lambdatronic S 3200 7 1 Large graphical display to show operating modes states of components and parameters 7 2 Status LED operating status green light flashing slowly boiler activated g...

Страница 9: ...3 Heat Exchanger Insulation Cover 14 Heat Exchanger Cover 15 Fuel Loading Chamber 16 Combustion Chamber 17 Flame Slot 18 Smoke Extraction Duct 19 Primary Air Damper Actuator 20 Secondary Air Damper Ac...

Страница 10: ...boiler is tested and listed to applicable UL CAN and other standards The boiler is not ASME stamped The installer should follow local or state installation requirements The FHG wood gasification boile...

Страница 11: ...per sonal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates a hazardous situation which if not avoided will result in death or serious...

Страница 12: ...r non permitted fuels will cause serious faults in combustion e g spontaneous combustion of carbonization gases or flash fires Instructions and guidelines for system configuration and minimum operatio...

Страница 13: ...ney must be 6 150 mm diameter listed UL 103 HT or ULC S629 residential all fuel type or tile lined masonry Flue connector pipe must be 6 150 mm diameter made of a minimum 24 MSG black steel Inadequate...

Страница 14: ...aterials Do not use chemicals gasoline oil or any other combustible fluids to start the fire Use of inappropriate fuels can result in Danger of Life or Severe Injury caused by explosive combustion and...

Страница 15: ...leaned regularly to remove accumulated creosote and ash Ensure that the Heat Exchanger Flue Gas Pipe and Chimney are cleaned at the end of heating season to minimize corrosion during the summer months...

Страница 16: ...ed for burning of cord wood only Wood briquettes or manufac tured pure wood logs can also be used as fuel provided they have a min imum cross section of 2 5 sq in 16 cm Manufactured logs should be at...

Страница 17: ...rganic materials and any other inappropriate materials Do not use chemicals or fluids to start the fire 2 2 3 Who may operate the boiler Non permitted use of the boiler by unauthorized persons can cau...

Страница 18: ...ictions and installation inspection in your area If there are no applicable local codes follow ANSI NFPA 211 and CAN CSA B365 Special precautions are required for passing the Chimney through a combust...

Страница 19: ...winter time The heating system must be able to carry all heat produced by the Cen tral Heating Boiler and additional heat source if applicable The whole heating system as well as all heating zones has...

Страница 20: ...es for Preventing the Boiler from overheating The FHG comes with safety systems to prevent the following Pressure in the boiler exceeding 30 psi over pressure Boiler water temperature exceeding 212 F...

Страница 21: ...10 of the boiler s maximum rated output Usually this heating zone is connected to the heating sys tem by a solenoid valve normally closed In case of electrical power failure the valve opens the Gravit...

Страница 22: ...er Control System In case no Emergency Off Switch is installed 1 Open Insulation Door slightly and keep it opened 2 Push DOWN Arrow Key at Boiler Control System to switch off In duced Draft Fan 3 Keep...

Страница 23: ...necessary amount of fuel within boiler area before opening boiler doors For usability and preparation of fire wood pay attention to chapter 2 2 within this manual For details refer to chapter 2 2 1 P...

Страница 24: ...y takes place at the end of operating mode Heating Refer to 3 4 Refueling the boiler For behavior in all other operating modes please refer to 4 1 3 Operating modes 3 1 5 Starting the boiler for the f...

Страница 25: ...d longer than four seconds For details refer to chapter 4 1 2 Graphical Display Turn off the Induced Draft Fan by pressing DOWN arrow key Light up the newspaper Turn on the Induced Draft Fan again by...

Страница 26: ...Do not heat up or recharge the boiler The Thermal Storage System is still too hot to store additional amount of energy 3 2 1 Inspect the burning flame Because opening the Combustion Chamber Door duri...

Страница 27: ...st start automatically you will hear the noise Cautiously open Fuel Loading Chamber Door keeping face away from opening Check the amount of combustion residues within the Filling chamber If level of a...

Страница 28: ...the Fuel Loading Chamber with the desired amount of fuel in accordance to heat demand shown by Thermal Storage System loading status symbol as described above Close Fuel Loading Chamber Door 3 3 3 Ign...

Страница 29: ...s fully finished In case of strong smell of smolder or fume coming out of the Ignition Door close Ignition Door and Insulation Door immediately and follow Caution instructions Explosive Gases at Cauti...

Страница 30: ...ly you will hear the noise Cautiously Open Fuel Loading Chamber Door keeping face away from opening Check the amount of un burnt fuel within the Filling chamber and de cide for refueling in accordance...

Страница 31: ...ation Keys Status LED Navigation Keys The navigation keys are for scrolling in the menu and changing parameter values Key Function for UP arrow Navigation Move up in the menu Parameter change Short ke...

Страница 32: ...rated load To exit this function Use Automatic Program below Long Service operation Function not used Automatic Program Short Automatic On Function not used exit other functions only Long Off Functio...

Страница 33: ...ation for every menu point or parameter The info text is also identified by the frame and the info symbol in the status line Info key for pending error messages If an error message was acknowledged af...

Страница 34: ...texts are also identified by a frame Shows activation of boiler See page 32 Function Keys not used Only shown in the Basic Display shows that the Thermal Storage System circulator is active not used n...

Страница 35: ...mpers are closed to the minimum opening If the temperature falls below the set point of boiler temperature the Boiler Control System returns to Heating mode Do not open Boiler Doors Do not refill fuel...

Страница 36: ...in parameters are only visible at specific User Levels To change to another level it is necessary to enter the relevant user code Child lock User Code 0 At Child lock level only the Basic Display is s...

Страница 37: ...er The following parameters however can should be set as desired by the Owner Desired target boiler temperature All temperature values at Boiler Control System are displayed in Centigrade or C only Te...

Страница 38: ...age System Storage tank 01 08 Display Description Storage tank top temperature 55 C Current temperature at Thermal Storage System top sensor Storage tank bottom temperature 50 C Current temperature at...

Страница 39: ...um value for heating circuit release for combination with a Thermal Storage System 4 6 Menu Boiler 4 6 1 Status Displays for the Boiler Display Description Boiler temperature 80 C Actual state values...

Страница 40: ...tware version Version 50 04 Build 04 12 4 7 2 Error See 6 3 Error messages at Boiler Control System 4 7 3 Basic Display parameters Basic Display Description Position 1 Position 2 The display of the tw...

Страница 41: ...ate and Time are used for display purposes only Format of Calendar Date Weekday 2 letters Day 2 digits Month 2 digits Year 2 digits e g MO 07 07 08 Monday 07th of July 2008 Format of Time Hour 2 digit...

Страница 42: ...f is displayed at the Boiler Control Sys tem Wait at least another hour for the boiler to cool down before starting any maintenance work Always wear protective gloves Always use control handles for op...

Страница 43: ...the Combustion Cham ber Open the Combustion Chamber Door Remove the ash using the rounded ash shovel Shovel the ash into the container intended to receive it Important Leave 1 of ash on the refractory...

Страница 44: ...deposits under the grate to ensure trouble free flow of secondary air Important After cleaning under the grates add 1 of ash on top of refractory and cast iron surfaces to protect them 5 2 4 Annual Ma...

Страница 45: ...uel Loading Chamber Door Clean the Smoke Extraction Duct with a small brush Combustion gases are sucked out when the Insulation Door is opened Take care not to push the brush into the Induction fan Ch...

Страница 46: ...er fail restart One hour after power has returned check system for normal operation and compare manometer reading to initial settings If system pressure is below replenish water to the heating system...

Страница 47: ...l continue to run usually When an error is detected The status LED 1 flashes red The error number and the relevant message text are shown in the graphic display The Error symbol is also displayed in t...

Страница 48: ...6 2 Excessive temperature Check switches for heating or circu lators pumps outside Boiler Con trol System Check circulator pump Reopen slide valves or cut offs check flow check valves or zone valves...

Страница 49: ...EMERGENCY OFF switch was activat ed Emergency Off Switch was activat ed In case no Emergency Off Switch is installed connection plugs shall be looped Follow emergency procedure In the event of runaway...

Страница 50: ...ction of the EEPROM memory does not work Ask your boiler dealer to check boiler control core module hard failure 71 009 EEPROM Write error Read or write function of the EEPROM memory does not work Ask...

Страница 51: ...ginal purchaser toward the cost of repair of the warranted item or if Tarm Biomass and the original purchaser agree use the resultant sum as a partial allowance toward Tarm Biomass replacement of the...

Страница 52: ...rty shall be entitled to recover all reasonable expenses it incurs in the action including its reasonable attorneys fees from the nonprevailing party TARM USA S LIMITED WARRANTY EXPRESSLY EXCLUDES COV...

Страница 53: ...6 86 186 8 150 302 235 455 54 129 2 88 190 4 155 311 240 464 56 132 8 90 194 160 320 245 473 58 136 4 92 197 6 165 329 250 482 60 140 94 201 2 170 338 255 491 62 143 6 96 204 8 175 347 260 500 64 147...

Страница 54: ...stra e 12 A 4710 Grieskirchen AUSTRIA PHONE 0043 0 7248 606 0 E MAIL info froling com INTERNET www froeling com 7 4 Importer Tarm Biomass 4 Britton Lane P O Box 285 Lyme NH 03768 PHONE 800 782 9927 E...

Отзывы: