Troubleshooting
Page 48
B0600008_US
v
6
6.3.1
Acknowledging a error message
Trace and remove the error cause and then:
Press Enter Key (6.3)
Status LED flashes green
6.3.2
List of possible error message
Error number /
Error message
Error information text /
Cause of Error
Troubleshooting
0
Hi-limit or e-stop
activated!!
Overheat Thermo-
stat (STL) or
EMERGENCY OFF
activated
The boiler has overheated through
strong reduction in heat consump-
tion
Customer switches for heating or
circulators (pumps) outside Boiler
Control System were switched off
Circulator (pump) suddenly stops
Slide valves, cut-off valves, flow-
check valves or zone-valves closed
Overheat Thermostat automatically
has been activated:
Reset Overheat Thermostat (STL)
after the boiler has cooled down
Refer to 6.2 Excessive temperature
Check switches for heating or circu-
lators (pumps) outside Boiler Con-
trol System
Check circulator (pump)
Reopen slide valves or cut-offs,
check flow-check valves or zone-
valves
1
Boiler temperature
sensor faulty
Sensor signal incorrect
Check sensor; ask a licensed elec-
trician to check sensor cable and
connections
2
Primary air damper
blocked
Deviation of more than 5% be-
tween position and control signal
for more than 5 minutes
Actuator not turning
Actuator incorrectly fitted
Incorrect direction of rotation
Movement of damper impeded
Connection cable defective
Check actuator and mechanics
Ask a licensed electrician to check
actuator cable and connections
Correct assembly: the damper
must be closed at primary air signal
0%
Ask a licensed electrician to swap
connections for "open" and "close"
at plug within Boiler Control Sys-
tem
Check to see if damper is jammed
Ask a licensed electrician to check
actuator cable and connections