Boiler Maintenance
Froling GmbH, Industriestraße 12, 4710 Grieskirchen, AUSTRIA
Page 43
www.froling.com
B0600008_US
5
5.2
Inspection, cleaning and maintenance
Regular cleaning of the boiler extends product life and is a basic re-
quirement for smooth running. So clean the boiler regularly!
5.2.1
Daily Maintenance / Before every firing
Cleaning of Heat Exchanger pipes
Activate the lever of the heat ex-
changer cleaning system (Efficiency
Optimization System EOS) several
times before the heating-up process
(5-10 times up and down)
5.2.2
Weekly Maintenance
Removing the ash
Open the Insulation Door and the
Ignition Door
Using the ash scraper, scrape the
ash located above the Combustion
Chamber into the Combustion Cham-
ber
Open the Combustion Chamber
Door
Remove the ash using the rounded
ash shovel
Shovel the ash into the container
intended to receive it
Important! Leave
½
”-1” of ash on
the refractory and cast iron surfaces to
protect them.
Use a Fire-proof container with a
cover!
Never use a vacuum to remove ash
from combustion or loading chamber.
This will drastically shorten the life of
the combustion stones.
IMPORTANT:
Ashes removed from the boiler should be placed in a metal container
with tightly fitting lid. The closed container of ashes should be placed
on a non-combustible floor or on the ground, well away from all
combustible materials, pending final disposal. If the ashes are dis-
posed of by burial in soil or otherwise locally dispersed, they should
be retained in the closed container until all cinders have thoroughly
cooled. Other waste should not be placed in this container