On the side with the door handle
❒ Close the door
➥ If the door can be opened with the usual force:
Setting okay
➥ If the door cannot be opened with the usual force or must be forced open
:push the locking plate toward the front
⇨ See "Positioning the doors" [page 27]
❒ Open the door
❒ Insert a sheet of paper at both the top and the bottom area at the side of the door
handle between the door and the boiler
❒ Close the door
❒ Try to pull the sheet of paper out
➥ If the paper cannot be removed:
the door seal is OK!
➥ If the paper can be removed:
the door is not sealed properly - push the locking plate toward the back!
⇨ See "Positioning the doors" [page 27]
Positioning the doors
❒ Using an Allen key (13 mm), loosen the nuts on the locking plate and/or hinge at
the top and bottom
❒ Use suitable tools (e.g. screwdriver and hammer) to move the locking plate and/or
hinge to the rear or the front as needed
➥ Caution: The locking plate and/or hinge must be aligned in the same way at the
top and bottom!
❒ Tighten the nuts at the top and bottom
Checking the setting:
Checking the seal:
Assembly
4
Before Installation
Installation Instructions S3 Turbo | M1080813_en
27
All manuals and user guides at all-guides.com