❒ Check to see if the air flaps can be opened to the right
➥ The exact position of the manual controller is set on initial start-up
⇨ See "Boiler with manual controller" [page 65]
❒ Use thread forming screws to secure the cover plate on the opposite side
Mounting the servo-motors (with S-Tronic Lambda control)
❒ Check to see if the air flaps are at the left stop
➥ All air flaps are closed
❒ Set the servo-motors:
➥ Set the direction of rotation of the servo-motor (1) to left (L)
➥ Press the unlock key (2) and turn the drive for the shaft to the air duct (3) in an
anti-clockwise direction as far as the stop
❒ Place the servo-motors onto the pneumatic rod
❒ Position the torque support and partially tighten the screws
❒ Align the servo-motors so that they are straight and tighten the screws
4
Assembly
Installing the boiler
52
Froeling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.at