❒ Push the tension lever downwards, remove the spring cotter and pull out the
eyebolt
❒ Flip the tension lever upwards and unhook the tension spring
➥ Note hole (A) of the tension spring
❒ Loosen the screw connection and remove the clamping lever
❒ Remove the tensioning bracket on the base plate
❒ Remove stop lever from drive lever
❒ Remove the holding bracket of the proximity sensor
❒ Position the holding bracket with the proximity sensor on the opposite side of the
filter system
➥ Pull out the cable of the proximity sensor from the control cabinet until the
cable length is sufficient
❒ Lay the cable of the proximity sensor in the cable duct
❒ Loosen the screw connection and unthread the securing plate
Assembly
5
Adapting the electrostatic precipitator system (if required)
Installation and Operating Instructions EF 250-500 | M2140120_en
23