18
GB
MODIFICATION.
7. VERSIONS AVAILABLE
REVERSING SINGLE DOORS
Cold storage appliances with a single door are normally
supplied with the door opening to the right (fig. 4).
If you require the door to open to the left, contact your
dealer who will supply you with the kit of springs and left-
hand hinges needed to reverse the door (fig.3).
Follow the instructions given below, referring to enclosed
diagram.
- Remove the console (fig.2).
- Remove the top RH hinge, paying attention to the
rotation force applied by the spring inside (fig.4).
- Remove the door, remove the U-bracket which trips the
microswitch, and reassemble on the other side of the
door.
- Remove the bottom right-hand hinge (fig.4).
- Fit the bottom left-hand hinge (fig.3).
- Fit the door into the bottom hinge.
- Fit the top left-hand hinge with its spring loaded by
about 3/4 of a revolution (fig.3).
- Fix the console.
REVERSING SPLIT DOORS
- Remove the console (fig.2).
- Remove the top right-hand hinge, top door, RH split
door hinge, bottom door and bottom right-hand hinge, in
that order.
When removing the top and split door hinges, pay
attention to the rotation force applied by the spring
inside.
- Remove the bottom door lock brackets and reassemble
on the other side of the same door.
- Fit the bottom left-hand hinge.
- Change the body gasket stop from right to left.
- Make two more M5 threaded holes in the gasket stop,
taking care not to damage the anti-condensation
heating element.
- Fit the door onto the bottom hinge.
- Fit the LH split door hinge with its spring loaded by
about 1/2 of a revolution.
- Fit the top door onto the split door hinge.
- Fit the top left-hand hinge with its spring loaded by
about 1/2 of a revolution.
- Fix the console.
8. WASTE DISPOSAL AND DEMOLITION
8.1 STORING WASTE
Special waste may be stored provisionally pending
disposal by means of treatment and/or definitive storage.
The environmental protection laws in the user's country
must always be complied with.
8.2 BASIC PROCEDURES FOR DISMANTLING THE
APPLIANCE
The legislation in force in the various countries varies;
take care to comply with the law in force in the countries
where demolition takes place.
In general, the cold storage appliance must be returned
to the dealer or to specialized centres for collection or
disposal.
When dismantling the appliance, group the components
together on the basis of their chemical nature.
Remember that the compressor contains lubricating oil
and refrigerating fluid, which can be recovered and
reused, and that the appliance components are special
waste which may be treated in the same way as
municipal waste.
THE APPLIANCE MUST BE DISMANTLED BY SKILLED
PERSONNEL.
9. INSTALLATION
This section contains information intended for skilled
technical staff.
9.1 TRANSPORTING AND HANDLING THE
PRODUCT
The appliance is of compact size, but this does not mean
that it can be carried around by hand.
It must be lifted using a fork-lift truck or pallet trolley,
taking great care to balance the weight.
The packaging normally consists of cardboard on a
pallet, and for greater safety during transport and
handling the pallet is secured to the bottom of the cabinet
using brackets, or held in place with tapes.
The warning symbols indicating the precautions which
must be taken to prevent damage during loading and
unloading, transport and storage are printed on the
packaging.
SYMBOLS USED ON OUR PACKAGING (UNI 6720-70):
THIS SIDE UP
FRAGILE
KEEP DRY
load and unload with care
The packaging may be kept and used again for any
reinstallation.
Users must always dispose of packaging materials in
accordance with the regulations in force in their countries.
Stacking limits
The stacking limit storage is 2 appliances; appliances
cannot be stacked during transport.
SINCE THE APPLIANCE'S CENTRE OF GRAVITY
DOES NOT LIE IN ITS GEOMETRICAL CENTRE, TAKE
CARE THAT IT DOES NOT TIP WHEN HANDLING.
9.2 INSTALLATION PROCEDURES
Unpack the appliance immediately on receipt to check
that no pieces have been lost or damaged in transit.
Inform the carrier of any damage at once. No damaged
appliances must be returned to the manufacturer without
prior written authorization.