Proper use of the dryer
10
– EN
ACT VS 3000 - 6000
3
Proper use of the dryer
This dryer has been designed, manufactured and tested for the purpose of separating the humidity normally contained
in compressed air. Any other use has to be considered improper.
The Manufacturer will not be responsible for any problem arising from improper use; the user will bear responsibility for
any resulting damage.
Moreover, the correct use requires the adherence to the installation instructions, specifically:
•
Voltage and frequency of the main power.
•
Pressure, temperature and flow-rate of the inlet air.
•
Pressure, temperature and cooling water capacity (Water-Cooled).
•
Ambient temperature.
This dryer is supplied tested and fully assembled. The only operation left to the user is the connection to the plant in
compliance with the instructions given in the following chapters.
Pos : 15 /Beko T ec hnis che D okument ati on/Übersc hriften/ 1/ Aussc hluss vom Anwendungs ber eich @ 0\ mod_1236003439359_6. doc @ 13709
4
Exclusion from a field of application
Pos : 16 /Beko T ec hnis che D okument ati on/Besti mmungsgemäß e Ver wendung/ BEKOM AT/ Aus schl uß Anwendung BM 31/ 32/33 @ 0\ mod_1236003837511_6.doc @ 13736
Note!
Improper use!
The device is intended for the separation of water in compressed air. The dried compressed air
cannot be used for breathing-air purposes and is not suitable for the direct contact with food.
This dryer is not suitable for the treatment of contaminated air or of air containing solids.
5
Instructions for the use of pressure equipment according to PED directive 2014/68/EU
To ensure the safe operation of pressure equipments, the user must conform strictly to the above directive and the
following:
1. The equipment must only be operated within the temperature and pressure limits stated on the m
anufacturer’s
data nameplate.
2. Welding on heat-exchanger is not recommended.
3. The equipment must not be stored in badly ventilated spaces, near a heat source or inflammable substances.
4. Vibration must be eliminated from the equipment to prevent fatigue failure.
5. Automatic condensate drains should be checked for operation every day to prevent a build up of condensate in
the pressure equipment.
6.
The maximum working pressure stated on the manufacturer’s data nameplate must not be exceeded. Prior to
use, the user must fit safety / pressure relief devices.
7. All documentation supplied with the equipment (manual, declaration of conformity etc.) must be kept for future
reference.
8. Do not apply weights or external loads on the vessel or its connecting piping.
TAMPERING, MODIFICATION AND IMPROPER USE OF THE PRESSURE EQUIPMENT ARE
FORBIDDEN. Users of the equipment must comply with all local and national pressure equipment
legislation in the country of installation.