17
PB
OPERATION
Function and Control
Service Manual
Technical Information
17
6. Function and Control
6.1 Introduction of Control Panel
1.Summary
When the unit is turned on, power indicator is displayed in green. In this case, you can operate the unit through control panel.
2.Operation interface and buttons
High
Low
Auto
Constant
Fan
Cool
Heat
Fan Speed
Mode
Temperature
Power
1
2
3
7
8
9
10
11
1.Fan speed and mode indicator
2.Heating mode button
3.Display window
4.Cooling mode button
5.Warmer/Cooler button
6.Constant fan mode button
7.Auto fan speed button
8.Low fan speed button
9.Power button
10.Power indicator
11.High fan speed button
Button function:
displaying indoor temperature for 15s; if pressing the Mode button in OFF mode, the controller will resume to the corresponding
operation status. Operation indicator will be on (Mode button includes Cool button and Heat button).
2.In ON status, each button is valid.
Power: After pressing the Power button, the unit can be switched between ON and OFF mode.
Cool button: In ON status, the unit will operate in cooling mode. In OFF mode, after pressing the Cool button, the controller will
operate according to cooling mode. Other functions will operate according to the status before turning off the unit.
Heat button: In ON status, the unit will operate in heating mode. In OFF mode, after pressing the Heat button, the controller will
operate according to heating mode. Other functions will operate according to the status before turning off the unit.
Constant Fan button: If constant fan mode is on, the fan motor will operate constantly. If constant mode is off, the fan will stop
as the load stops. The fan speed is controlled by the fan speed button (If wired controller is connected, the fan speed follows the
command of the wired controller. The controller will control if the fan shall operate or not).
Auto button: When the unit is on, press Auto button to select auto fan speed.
Low button: When the unit is on, press Low button to select low fan speed.
High button: When the unit is on, press High button to select high fan speed.
o
F(16~30
o
C) and you can also select other set
4
5
6
Содержание PDE07K Series
Страница 23: ...23 OPERATION DipSwitchFunction 3 4 4 Dip Switch Functions Settings Dip Switch 3 and 4 Disable No Function ...
Страница 39: ...39 UNIT DISASSEMBLY IndoorMotor Wheel HeatingElementAssembly FIGURE 401 Removal of Indoor Fan Wire Harness ...
Страница 41: ...41 UNIT DISASSEMBLY Indoor Motor Wheel Heating Element Assembly FIGURE 403 Removal of Indoor Fan Grommet ...
Страница 42: ...42 UNIT DISASSEMBLY Indoor Motor Wheel Heating Element Assembly Figure 404 Left side Bushing Bushing Housing ...
Страница 47: ...47 UNIT DISASSEMBLY Indoor Motor Wheel Heating Element Assembly Figure 409 Primary Secondary Limits ...
Страница 48: ...48 UNIT DISASSEMBLY OutdoorMotor Blade ShroudAssembly Figure 410 Remove Gussets and Fan Shroud ...
Страница 50: ...50 UNIT DISASSEMBLY ElectronicBoard ElectricalComponentReplacement Figure 412 Remove User Interface ...
Страница 51: ...51 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 413 Remove User Interface ...
Страница 52: ...52 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement FIGURE 414 Low Voltage Connections ...
Страница 53: ...53 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 415 Power Cord and Housing ...
Страница 56: ...56 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 418 Main Board Relay Board ...
Страница 58: ...58 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 420 Transformer ...
Страница 59: ...59 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 421 Transformer Removed ...
Страница 96: ...96 COMPONENTS TESTING TestingLineVoltage 208 230 265V AC FIGURE 709 LINE VOLTAGE ...