background image

20

21

920-138-02 (3-04)

920-138-02 (3-04)

Friedrich Air Conditioning Company 

P.O. Box 1540

San Antonio, TX 78295 

(210) 357-4400 

WALL-MOUNT

SINGLE PACKAGE AIR CONDITIONERS 

LIMITED WARRANTY 

TELECOMMUNICATIONS AND SIMILAR APPLICATIONS 

(SEE SPECIFIC WARRANTY FOR COMFORT COOLING APPLICATIONS) 

1.  A)  ONE (1) YEAR PARTS WARRANTY - FRIEDRICH AIR CONDITIONING CO. (FRIEDRICH)

 warrants to the original end-user of this 

product that should any component part prove defective due to improper workmanship and/or material under normal use for a period of one 

(1) year from the date of original installation, FRIEDRICH will repair or replace, at its option, any defective part without charge for the part.  

Replacement parts are warranted for the remainder of the original warranty period. 

B)  FIVE (5) YEAR COMPRESSOR WARRANTY - FRIEDRICH AIR CONDITIONING CO. (FRIEDRICH)

 warrants to the original end-

user of this product that should the compressor prove defective due to improper workmanship and/or material under normal use for a period 

of Five (5) years from the date of original installation, FRIEDRICH will repair or replace, at its option, the compressor without charge for the 

part.  Replacement compressors are warranted for the remainder of the original warranty period. 

C)  THESE WARRANTIES DO NOT INCLUDE LABOR

 or other costs incurred for servicing, repairing, removing, installing, shipping, or 

handling of either defective or replacement parts, or complete unit.  Such costs may be covered by a separate warranty provided by the 

installing contractor. 

2.  

Any defective part to be replaced must be made available to

 FRIEDRICH

 in exchange for the replacement part.  You must present proof 

of the original date of installation of the product in order to establish the effective date of the  warranty.  Otherwise, the effective date will be 

deemed to be the date of manufacture plus thirty days.  The return of the owner registration card is not a condition of warranty coverage.  

However, please detach and return it so that we can contact you should a question of safety arise which could affect you. 

3. TO OBTAIN SERVICE

 and/or warranty parts replacement

,

please contact the dealer or contractor who installed or has been servicing the 

equipment within the applicable warranty period.  If your dealer or contractor needs assistance, the authorized 

FRIEDRICH

 distributor is 

available for consultation, and 

FRIEDRICH

 supports the efforts of the distributor. 

4.

 This limited warranty applies only to units remaining at the site of the original installation (except for mobile home installations) and only 

to units installed within the continental United States, Alaska, Hawaii, and Canada.  This limited warranty applies only if the unit is installed 

and operated in accordance with FRIEDRICH instructions and in compliance with applicable local installation and building codes and good 

trade practices. 

5.  THIS WARRANTY DOES NOT COVER

 units installed in over the road trucks, vans, and trailers, or damages caused by:  (a) accident, 

abuse,  negligence,  or  misuse;    (b)  operating  the  product  in  a  corrosive  atmosphere  containing  chlorine,  fluorine  or  any  other  damaging

chemicals; (c) modification, alteration, poor service practices;  (d) improper matching or application of the product or components;  (e) failure 

to provide proper maintenance and service to the product according to manufacturer's instructions; (f) installation or operating of the product 

in  a  manner  contrary  to  the  instructions  of  the  manufacturer;  (g)  lightning,  fluctuations  in  electrical  power  or  other  Acts  of  God.    This 

LIMITED WARRANTY

 also excludes all cost of installation, disconnection or dismantling the product, parts used in connection with normal 

maintenance  such  as  air  filters  and  owner-required  maintenance.    Consult  the  instructions  enclosed  with  the  product  for  information

regarding recommended maintenance. 

6.  

No one is authorized to change this

 LIMITED WARRANTY

 in any respect, or to create any other obligation or liability in connection with 

this product. 

7.  YOUR ONLY REMEDIES ARE PROVIDED IN THIS LIMITED WARRANTY.  ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, 

AND  ANY  REMEDY  WHICH,  BUT  FOR  THIS  PROVISION,  MIGHT  ARISE  BY  IMPLICATION  OR  OPERATION  OF  LAW,  IS  HEREBY 

EXCLUDED  AND  DISCLAIMED.    THE  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  AND  OF  FITNESS  FOR  ANY  PARTICULAR 

PURPOSE  ARE  EXPRESSLY  LIMITED  TO  A  TERM  OF  ONE  YEAR  FROM  THE  DATE  OF  ORIGINAL  INSTALLATION.    UNDER  NO 

CIRCUMSTANCES SHALL FRIEDRICH BE LIABLE TO THE OWNER OR ANY OTHER PERSON FOR ANY INCIDENTAL, SPECIAL OR 

CONSEQUENTIAL  DAMAGES  IN  CONNECTION  WITH  THIS  PRODUCT,  WHETHER  ARISING  OUT  OF  BREACH  OF  WARRANTY, 

BREACH OF CONTRACT OR OTHERWISE. 

8.

 Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental,

special or consequential damages, so the above limitations or exclusions may not apply to you. 

9.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state and province to province.

(12/03)

Содержание OES Series

Страница 1: ...Wall Mount Outdoor Wall mounted Air Conditioners Heat Pumps OES OHS Series 920 138 02 3 04 Installation Operation Manual...

Страница 2: ...Model Information Form 19 Warranty Information 20 21 TABLE OF CONTENTS Please read this manual thoroughly prior to equipment installation or operation It is the installer s responsibility to properly...

Страница 3: ...208 230V 1 PH 60HZ Chassis Color X Alaskan Beige standard Future Revision Digit Figure 2 Unit Dimensions MODEL DIMENSIONS A B C D E F G H I J K L M N O P Q R S T OES OHS18 24 36 9 20 0 6 2 7 9 20 1 2...

Страница 4: ...0B for special installation requirements Recognize safety information This is the safety alert symbol When you see this symbol on the unit or in instructions and manuals be alert to the potential for...

Страница 5: ...external static pressures The supply and return air duct system pressure losses including filter louver grille and registers must not exceed the listed external static pressures for the indoor air sys...

Страница 6: ...filters monthly Replace disposable type filters before they become clogged Use water and mild detergent to clean washable type filters NOTE Most filters are marked with an arrow to indicate the proper...

Страница 7: ...o the rear of the cabinet See Figure 5 Repeat the above steps for each of the eight perforated metal flanges on the rear of the cabinet When completed there will be eight duct flanges that are perpend...

Страница 8: ...in flashing to the back flange of the unit top by using screws in the top panel Top rain flashing is shipped secured to the back of the unit See Figure 9 5 Position the unit in the opening and secure...

Страница 9: ...may be required for some walls Framing Material 2 x 4 s 2 x 6 s and or structural steel See Unit Dimensions Figure 2 for duct dimensions See Unit Dimensions Figure 2 for actual dimensions SUPPLY AIR O...

Страница 10: ...g its entire length Top Front of unit Wall Structure SUPPLY AIR DUCT RETURN AIR DUCT NOTE It is recommended that a bead of silicone be placed behind the side mounting flanges and under the top flashin...

Страница 11: ...d local codes national electric code and NFPA 70 Unit and controls will NOT operate unless properly grounded A ground lug is provided for ground connection Use only approved copper wire and connectors...

Страница 12: ...A 30 N A 10 N A 10 N A 19 9 30 10 10 05 2 230 208 60 1 198 253 19 9 26 0 30 30 10 10 10 10 28 30 10 10 08 2 230 208 60 1 198 253 19 9 39 0 30 40 10 8 10 10 41 50 6 10 10 2 230 208 60 1 198 253 19 9 52...

Страница 13: ...30 8 10 10 10 51 60 6 10 08 2 230 208 60 1 198 253 22 8 39 0 40 40 8 8 10 10 64 70 4 8 10 2 230 208 60 1 198 253 22 8 52 0 40 60 8 6 10 10 77 80 4 8 15 2 230 208 60 1 198 253 22 8 39 0 40 40 8 8 10 10...

Страница 14: ...Fully closed halfway open and fully open Fully open provides 15 of rated airflow of outside air The damper position is fixed Adjustment 1 Remove louvered panel from unit See Figure 11 2 Remove one 1...

Страница 15: ...aneltogainaccesstothedampermotorcontrol Adjust the thumb wheel on the back of the motor to achieve desired set point Figure 13 Commerical Room Ventilator Components Thumbwheel Fresh Air Damper Shaft E...

Страница 16: ...ns closed and energizes the compressor for cooing operation Adjustment 1 1 2 5 Ton Chassis 1 Step 1 2 for 1 1 2 3 ton models only Through the return air opening remove two 2 screws on the access cover...

Страница 17: ...is not required to be mixed with conditioned air Units with vent packages have louvered front panels to allow for air intake Units without ventilation packages have a BOP blank off plate instead of a...

Страница 18: ...cuit breakers inside unit are ON 2 Check to see if all duct work is sealed to unit for an airtight fit 3 Thermostat is level and properly installed Heat anticipator indicator is set to the correct set...

Страница 19: ...L MOUNT MODEL WALL MOUNT SERIAL IF WALL MOUNT WAS PURCHASED INSTALLED IN A MANUFACTURED STRUCTURE DATE OF PURCHASE DEALER NAME DEALER PHONE DEALER FAX DEALER ADDRESS DEALER CITY STATE ZIP MANUFACTURER...

Страница 20: ...da This limited warranty applies only if the unit is installed and operated in accordance with FRIEDRICH instructions and in compliance with applicable local installation and building codes and good t...

Страница 21: ...stributor 4 This limited warranty applies only to units remaining at the site of the original installation except for mobile home installations and only to units installed within the continental Unite...

Страница 22: ...22 920 138 02 3 04...

Страница 23: ...23 920 138 02 3 04...

Страница 24: ...2 3 04 FRIEDRICH AIR CONDITIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com Printed in...

Отзывы: