En-10
knob(two places)
Right-Left Louvers
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left)
airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.
Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction
louvers are stopped.
R
DANGER!
●
Never place fingers or foreign objects in-
side the outlet ports, since the internal fan
operates at high speed, and personal injury
could be caused.
●
Always use the Remote Control Unit’s
SET button to adjust the vertical airflow
louvers. Attempting to move them
manually could result in improper op-
eration; in this case, stop operation and
restart. The louvers should begin to
operate properly again.
●
During use of the Cooling and Dry
modes, do not set the Airflow Direc-
tion Louvers in the Heating range
(4 - 6) for many hours, since water
vapor may condense near the outlet
louvers and drops of water may drip
from the indoor unit. During the Cool-
ing and Dry modes, if the Airflow Di-
rection Louvers are left in the heating
range for more than 30 minutes, they
will automatically return to position 3.
●
When used in a room with infants, chil-
dren, elderly or sick persons, the airflow
direction and room temperature should
be considered carefully when making
settings.
Vertical Air Direction Adjustment
Press the SET button (Fig. 6 b-11).
Each time the button is pressed, the air direction range will change as follows:
1
2
3
4
5
6
Types of Air flow Direction Setting:
For better heating/cooling effect, it is recommended to set the air direction in the
following range.
1, 2, 3 :
During Cooling/Dry modes
4, 5, 6 :
During Heating mode
The Remote Control Unit’s display does
not change.
●
Use the air direction adjustments within the ranges shown above.
●
The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
During Heating mode
: Downward flow 6
●
During AUTO/HEAT mode operation, for the first one minute after beginning op-
eration, airflow will be horizontal 1; the air direction cannot be adjusted during
this period.
The air flow direction setting will temporarily become 1 when the temperature of
the air flow is low at the start of the Heating mode.
Right-Left Adjustment
Adjust the Right-Left louvers.
●
Move the Right-Left louvers to adjust air flow in the direction you prefer.
R
DANGER!
●
When adjusting the Right-Left Louvers, it
is necessary to stop the Air-Conditioner
first and make sure that it stops completely
before adjusting the direction.
1
2
3
4
5
6
knob