En-15

TROUBLESHOOTING

Symptom

Doesn’t operate at all:

Poor Cooling performance:

The unit operates
differently from the Remote
Control Unit’s setting:

See Page

8 - 9

6

5

CHECK ONCE

MORE

Items to check

Is the Power Supply Plug disconnected its outlet?

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the timer operating?

Is the Air Filter dirty?

Air the air conditioner’s intake grille or outlet port blocked?

Did you adjust the room temperature settings (thermostat) cor-
rectly?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)

In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?

Is the unit set for SUPER QUIET operation?

Are the Remote Control Unit’s batteries dead?

Are the Remote Control Unit’s batteries loaded properly?

OPERATING TIPS

If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp
(Fig. 3 a-5) and  the TIMER Indicator Lamp (Fig. 3 a-6) flashes, immediately stop operation, disconnect the Power Supply
Plug, and consult authorized service personnel.

Operation and Performance

Heating Performance

This air conditioner operates on the heat-pump princi-
ple, absorbing heat from outdoor air and transferring that
heat to indoor unit. As a result, the operating perform-
ance is reduced as outdoor air temperature drops. If you
feel that insufficient heating performance is being
produced, we recommend you use this air conditioner in
conjunction with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.

Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low
outdoor temperature and high humidity, frost may form
on the outdoor unit, resulting in reduced operating per-
formance.

In order to prevent this kind of reduced performance, this
air conditioner is equipped with a Microcomputer-
controlled Automatic Defrosting function. If frost forms,
the air conditioner will temporarily stop, and the
defrosting circuit will operate briefly (for about 7-15 min-
utes).

During Automatic Defrosting operation, the OPERATION
Indicator Lamp (green) will flash.

AUTO Restart

In Event of Power Interruption

The power supply to the air conditioner is stopped by a
power interruption. The air conditioner will then restart
automatically in its previous mode when the power is
restored.

If a power interruption occurs during TIMER operation, the
timer will be reset and the indoor unit will begin (or stop)
operation at the new time setting. In the event that this kind
of timer fault occurs, the TIMER Indicator Lamp will flash
(see Page. 4).

Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
disconnect the Power Supply Plug, reconnect it, and then
use the Remote Control Unit to resume operation.

www.sylvane.com  1-800-934-9194

Содержание MR09Y3H

Страница 1: ...English Espa ol Fran ais MODE D EMPLOI MANUAL MW09Y3H MW12Y3H MR09Y3H MR12Y3H CONSERVEZ CE MODE D EMPLOI POUR R F RENCE ULT RIEUR 9332280005 01 www sylvane com 1 800 934 9194...

Страница 2: ...placed by the authorized service personal since special purpose tools and specified cord are required Provide occasional ventilation during use Do not direct airflow at fireplaces or heating apparatus...

Страница 3: ...set time is reached the indoor unit au tomatically turns off WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of indoor unit operation SWING OPERATION The Air...

Страница 4: ...explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current op eration...

Страница 5: ...nit a 17 Drain port bottom Fig 6 Remote Control Unit b 1 Signal Transmitter b 2 MODE button b 3 MIN HEAT button b 4 SET TEMP button b 5 COIL DRY button b 6 SLEEP button b 7 TIMER MODE button b 8 FAN b...

Страница 6: ...w while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 b 14 Use t...

Страница 7: ...About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed P...

Страница 8: ...peed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room tempe...

Страница 9: ...the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from O...

Страница 10: ...Operation Press the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance w...

Страница 11: ...m with infants chil dren elderly or sick persons the airflow direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button F...

Страница 12: ...m output ECONOMY Operation is approximately 70 of normal air conditioner operation for cooling and heating When ECONOMY operation is performed during the cooling mode dehumidification is improved This...

Страница 13: ...lay Fig 7 c 10 will light Then it will disappear after 10 seconds To cancel COIL DRY Operation Press the START STOP button Fig 6 b 9 during COIL DRY Operation The indoor unit COIL DRY Indicator Lamp y...

Страница 14: ...nd push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the indoor unit without Intak...

Страница 15: ...in con densation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation i...

Страница 16: ...ent heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculat...

Страница 17: ...ading to water leakage and other damage Do not use this air conditioner for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings If the air cond...

Страница 18: ...Friedrich Air Conditioning Co 4200 N Pan Am San Antonio Texas 78218 USA Tel 210 357 4400 Fax 210 357 4490 Visit us at www friedrich com www sylvane com 1 800 934 9194...

Отзывы: