background image

 

A.

³⁄₄ 

" (19.1 mm) extending into room

B. Trim

B

A

A. Level

A

Use 2" x 4" or thicker lumber for wood frame.

4.

Apply wood preservative to the outside exposed surface.

5.

Insert the frame in the wall opening. Square and level frame. 

6.

Attach frame securely to the wall.

Install Cabinet into Wood Frame

1.

Remove top channel and both side channels using a 

¹⁄₄

" nut 

driver or socket wrench. Discard top channel and both side 
channels.

A. Outside width
B. Outside height

C. Depth

A

B

C

3.  Insert cabinet into the framed wall opening. the top of the cbine

should extend ¾" (19.1 mm) into the room. If there is trim, the
cabinet should extend ¾" (19.1 mm)  past the trim.

5.  Check that air conditioner cabinet is tilted to the outside so that

water will run to the outside.

6.  Reuse the insulation to seal opening between cabinet and

frame. 

7. Use 

existing holes in sides and top of cabinet and 7 - #10 x 1"

wood screws (not provided) to attach cabinet to frame.

NOTE:

 Do not overtighten screws or cabinet will distort and

provide a poor air seal between cabinet and air conditioner.

8.  Caulk all outside wall openings around cabinet.

4.  Use a level to check that cabinet is level side to side.

Complete Installation

NOTE: 

Handle air conditioner carefully and gently.

1.

Make sure the free end of the ground wire is outside of the 
cabinet.

2.

Insert air conditioner into cabinet. 

A

A

A. Make sure the free end of the ground wire is outside of the cabinet.

¾" Minim

Cabinet fro

1" Thick lumbe

1" Minim

Inside wall

Exterior wa

mum

nt

er

mum

wall

¼" Slope down. 

Position and secure cabinet 

downward. Slope outside for 
drainage.

Max. Wall thickness allowed 8 ½"

Front edge of louvers must always
be outside of exterior wall surface

2.

Cut two pieces of standard 1" lumber (supplied by installer) to the 

i

f t d d 1" l

b

(

li d b i t

length and width required. Place in front and back of bottom sill 
channel. Secure with nails (supplied by installer).

to move and install

10

Содержание CP15F10

Страница 1: ... CP15F10A ...

Страница 2: ......

Страница 3: ...llation on some models 7 Through the Wall Cabinet Installation 9 Complete Installation 10 Air Conditioner Use 11 Starting Your Air Conditioner Digital Control 12 Remote Control Operation 13 Normal Sounds 13 Air Conditioner Care 14 Cleaning the Air Filter r 14 Cleaning the Front Panel 14 Repairing Paint Damage 14 Annual Maintenance 14 Troubleshooting 14 Assistance or Service 15 Warranty 16 1 ...

Страница 4: ...technicians should service this equipment R410A systems operate at higher pressures than R22 equipment Appropriate safe service and handling practices must be used Only use gauge sets designed for use with R410A Do not use standard R22 gauge sets Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read ...

Страница 5: ...K pan head Phillips screws 2 K ...

Страница 6: ...ted in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number nameplate label The model and serial number label is located behind the front panel on the flange below the control panel area Specific electrical requirements are listed in the chart below Follow the requirements for the type of ...

Страница 7: ...quipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button w...

Страница 8: ......

Страница 9: ...and then bottom of right hand curtain housing in top and bottom curtain channels on air conditioner Top view Bottom view 3 Extend right hand curtain outward so you may insert the first screw through the middle hole of the curtain Using 10 x pan head Phillips screw screw curtain to middle hole in air conditioner cabinet NOTE This screw is required to correctly attach curtain top to bottom to the ai...

Страница 10: ...7 ...

Страница 11: ...1 2 ...

Страница 12: ...t and 7 10 x 1 wood screws not provided to attach cabinet to frame NOTE Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and air conditioner 8 Caulk all outside wall openings around cabinet 4 Use a level to check that cabinet is level side to side CompleteInstallation NOTE Handle air conditioner carefully and gently 1 Make sure the free end of the groun...

Страница 13: ...and 2 9 5X 3 8 pan head Phillips screws attach front of panel to chassis ...

Страница 14: ...us or minus button to change the delay time from 1 to 24 hours 3 Press TIMER or wait 10 seconds Indicator light will remain on To set the Timer delay for a 1 to 24 hour delay until the air conditioner turns on keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light will flash 3 Press the plus or minus button to change the delay time from 1 to 24 hours 4 Press TIMER or wa...

Страница 15: ...ol panel will flash 2 Press the plus or minus button to change the delay time from 1 to 24 hours 3 Press TIMER again or wait 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light on air conditioner control panel will flash 3 Press the plus or minus button ...

Страница 16: ...on after turning the unit off Wait at least 3 minutes after turning the unit off before trying to restart the air conditioner Cleaningthe FrontPanel 1 Turn off air conditioner 2 Remove the air filter and clean it separately See Cleaning the Air Filter 3 Wipe the front panel with a soft damp cloth 4 Air dry front panel completely Repairing Paint Damage Check once or twice a year for paint damage Th...

Страница 17: ...liances during the hottest part of the day The louvers are blocked Install the air conditioner in a location where the louvers are free from curtains blinds furniture etc The outside temperature is below 65 F 18 C Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 65 F 18 C The temperature of the room you are trying to cool is extremely hot Allow e...

Страница 18: ...ics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by war government restrictions or restraints strikes material shortages beyond the control of FRIEDRICH or acts of God OBTAINING WARRANTY PERFORMANCE Service will be provided by the FRIEDRICH Aut...

Страница 19: ......

Страница 20: ...66129903813 1 800 541 6645 ...

Отзывы: