Power supply
cord
Wiring requirements
■
115-volt (103.5 min. - 126.5 max.)
■
0-12 amps
■
15-amp time-delay fuse or circuit breaker
■
Use on single outlet circuit only.
■
230-volt (207 min. - 253 max.)
■
0-12 amps
■
15-amp time-delay fuse or circuit breaker
■
Use on single outlet circuit only.
¹⁄₄
"
(0.6 cm)
The wall opening measurements should be:
Height (A): 17 ¼" plus twice thickness of wood used to build
frame
Width (B): 26 ¼"
Depth (D): 4" minimum to 8" maximum.
Electrical Requirements
Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the
model and serial number (nameplate) label. The model and serial
number label is located behind the front panel on the flange below
the control panel area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Window installation
Window opening measurements:
27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A).
20" min. (50.8 cm) opening height (B).
Through-the-wall installation
A.
27
" min. (76.2 c m)
B . 20" min. (50.8 c m)
A
B
A. 17 ¼"
B. 26 ¼"
C. Wood thickness
D. 4" minimum to
8" maximum.
CP1
5
CP18 / CP24
4
Содержание CP15F10
Страница 1: ... CP15F10A ...
Страница 2: ......
Страница 5: ...K pan head Phillips screws 2 K ...
Страница 8: ......
Страница 10: ...7 ...
Страница 11: ...1 2 ...
Страница 13: ...and 2 9 5X 3 8 pan head Phillips screws attach front of panel to chassis ...
Страница 19: ......
Страница 20: ...66129903813 1 800 541 6645 ...