background image

This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit.  For 

years of trouble-free service, please follow the installation instructions closely.  We cannot overemphasize the importance of 

proper installation.  We have added new information to the basic instructions to help you achieve success.

General Instructions

     

WARNING

Please read this manual thoroughly prior to equipment 

installation or operation.  
It is the installer’s responsibility to properly apply and 

install  the  equipment.    Installation  must  be  in 

conformance with the NFPA 70-2008 National Electric 

Code or current edition, International Mechanic Code 

2009 or current edition and any other applicable local 

or national codes.
Failure  to  do  so  can  result  in  property  damage, 

      

personal injury 

and / 

or death.

     

WARNING

Refrigeration system under high pressure.

Do not puncture, heat, expose to flame or incinerate.
Only  certified  refrigeration  technicians  should  service 

this equipment.
R410A systems operate at higher pressures than R22 

equipment.  Appropriate  safe  service  and  handling 

practices must be used.
Only use gauge sets designed for use with R410A. Do 

not use standard R22 gauge sets.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual 

and on your appliance. Always read and obey all safety messages. 

This is a safety Alert symbol. This symbol alerts you 

to  potential  hazards  that  can  kill  or  hurt  you  and 

others.

All  safety  messages  will  follow  the  safety  alert 

symbol with the word “WARNING” or “CAUTION”. 

These words mean:

WARNING

Indicates  a  hazard  which,  if  not 

avoided,  can  result  in  severe 

personal injury or death and damage 

to product or other property.

CAUTION

Indicates  a  hazard  which,  if  not 

avoided, can result in personal injury 

All safety messages will tell you what the potential hazard is, tell you 

how to reduce the chance of injury, and tell you what will happen if 

the instructions are not followed.

and  damage to product or other property.

NOTICE

Indicates  property  damage  can 

occur  if  instructions  are  not 

followed.

2

Содержание CP15F10

Страница 1: ... CP15F10A ...

Страница 2: ......

Страница 3: ...llation on some models 7 Through the Wall Cabinet Installation 9 Complete Installation 10 Air Conditioner Use 11 Starting Your Air Conditioner Digital Control 12 Remote Control Operation 13 Normal Sounds 13 Air Conditioner Care 14 Cleaning the Air Filter r 14 Cleaning the Front Panel 14 Repairing Paint Damage 14 Annual Maintenance 14 Troubleshooting 14 Assistance or Service 15 Warranty 16 1 ...

Страница 4: ...technicians should service this equipment R410A systems operate at higher pressures than R22 equipment Appropriate safe service and handling practices must be used Only use gauge sets designed for use with R410A Do not use standard R22 gauge sets Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read ...

Страница 5: ...K pan head Phillips screws 2 K ...

Страница 6: ...ted in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number nameplate label The model and serial number label is located behind the front panel on the flange below the control panel area Specific electrical requirements are listed in the chart below Follow the requirements for the type of ...

Страница 7: ...quipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button w...

Страница 8: ......

Страница 9: ...and then bottom of right hand curtain housing in top and bottom curtain channels on air conditioner Top view Bottom view 3 Extend right hand curtain outward so you may insert the first screw through the middle hole of the curtain Using 10 x pan head Phillips screw screw curtain to middle hole in air conditioner cabinet NOTE This screw is required to correctly attach curtain top to bottom to the ai...

Страница 10: ...7 ...

Страница 11: ...1 2 ...

Страница 12: ...t and 7 10 x 1 wood screws not provided to attach cabinet to frame NOTE Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and air conditioner 8 Caulk all outside wall openings around cabinet 4 Use a level to check that cabinet is level side to side CompleteInstallation NOTE Handle air conditioner carefully and gently 1 Make sure the free end of the groun...

Страница 13: ...and 2 9 5X 3 8 pan head Phillips screws attach front of panel to chassis ...

Страница 14: ...us or minus button to change the delay time from 1 to 24 hours 3 Press TIMER or wait 10 seconds Indicator light will remain on To set the Timer delay for a 1 to 24 hour delay until the air conditioner turns on keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light will flash 3 Press the plus or minus button to change the delay time from 1 to 24 hours 4 Press TIMER or wa...

Страница 15: ...ol panel will flash 2 Press the plus or minus button to change the delay time from 1 to 24 hours 3 Press TIMER again or wait 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light on air conditioner control panel will flash 3 Press the plus or minus button ...

Страница 16: ...on after turning the unit off Wait at least 3 minutes after turning the unit off before trying to restart the air conditioner Cleaningthe FrontPanel 1 Turn off air conditioner 2 Remove the air filter and clean it separately See Cleaning the Air Filter 3 Wipe the front panel with a soft damp cloth 4 Air dry front panel completely Repairing Paint Damage Check once or twice a year for paint damage Th...

Страница 17: ...liances during the hottest part of the day The louvers are blocked Install the air conditioner in a location where the louvers are free from curtains blinds furniture etc The outside temperature is below 65 F 18 C Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 65 F 18 C The temperature of the room you are trying to cool is extremely hot Allow e...

Страница 18: ...ics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by war government restrictions or restraints strikes material shortages beyond the control of FRIEDRICH or acts of God OBTAINING WARRANTY PERFORMANCE Service will be provided by the FRIEDRICH Aut...