Starting Your Air Conditioner—Digital Control

1.

Press POWER to turn on air conditioner.

NOTE: 

When the unit is turned on, it will display the previous 

settings for the Mode, Fan Speed and temperature.

2.

Choose mode. See “ Mode.”

3.

Choose fan speed. See “ Fan Speed.”

4.

Choose temperature. See “ Temperature.”

Mode

1.

Press and hold MODE.

2.

Cool—Cools room. Press FAN SPEED to choose fan 
speed. Then adjust the temperature by pressing the up or 
down arrow buttons.

Fan—Operates the fan at 

High

 speed, without cool ing. 

The display shows “ FO”  (fan only).

Fan Speed 

NOTE: 

The Fan Speed button will operate when the Cool

,

 

Money

 Saver 

or

 

Fan

 

Only

 

mode ha

s

 been selected.

1. Press 

the Fan Speed

 

button 

until you see the indicator light 

for the desired setting.

2. Choose 

Low, Medium or High

.

Temperature

 

Press, or press and hold, the plus button to raise the 
temperature 1º until it reaches 

90

ºF (

32.2º

C). 

Press, or press and hold, the minus button to lower the 
temperature 1º until it reaches 

60

ºF (1

5.5º

C).

Timer Delay

To set the Timer for a 1- to 24-hour delay until the air 
conditioner turns off (the air conditioner must be On):

1. Press TIMER. Indicator light will flash. 

2. Press the plus or minus button to change the delay time from 

1 to 24 hours.

3. Press TIMER or wait 10 seconds. Indicator light will remain 

on.

To set the Timer delay for a 1- to 24-hour delay until the air 
conditioner turns on, keeping previous settings:

1. Turn off air conditioner.

2. Press TIMER. Indicator light will flash.

3. Press the plus or minus button to change the delay time from 

1 to 24 hours.

4. Press TIMER or wait 10 seconds. Indicator light will remain 

on.

To set the Timer delay for a 1- to 24-hour delay until the air 
conditioner turns on, changing previous settings:

1. Turn on air conditioner.

2. Adjust MODE to desired setting.

3. Adjust FAN SPEED to 

Low,

 

Medium

 or

 

High.

4. Adjust temperature between 6

0

ºF (

15.5º

C) and 

90

ºF (

32.2º

C).

5. Turn off air conditioner.

6. Press TIMER. Indicator light will flash.

7. Press the plus or minus button to ch ange delay time from 1 to 

24 hours.

8. Press TIMER or wait 10 seconds.

To clear Timer delay program

NOTE:

 Air conditioner can be either on or off.

Press TIMER. Indicator light will turn off.  

POWER

Temp/Hour

Timer

Fan Speed

Fan Only

Cool

Money

Saver

®

High
Med
Low

0

F

Mode

Hr.

Auto Swing

Temp/Hour

0

F

Hr.

Timer

Money Saver —

 Cycles fan with compressor when

room temperature 

reaches the temperature setting 

on the thermostat.

Fan Only

Cool

Mode

Money

Saver

®

Fan Speed

High
Med
Low

POWER

Money Saver

®

Choose Cool or Fan mode

12

Содержание CP15F10

Страница 1: ... CP15F10A ...

Страница 2: ......

Страница 3: ...llation on some models 7 Through the Wall Cabinet Installation 9 Complete Installation 10 Air Conditioner Use 11 Starting Your Air Conditioner Digital Control 12 Remote Control Operation 13 Normal Sounds 13 Air Conditioner Care 14 Cleaning the Air Filter r 14 Cleaning the Front Panel 14 Repairing Paint Damage 14 Annual Maintenance 14 Troubleshooting 14 Assistance or Service 15 Warranty 16 1 ...

Страница 4: ...technicians should service this equipment R410A systems operate at higher pressures than R22 equipment Appropriate safe service and handling practices must be used Only use gauge sets designed for use with R410A Do not use standard R22 gauge sets Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read ...

Страница 5: ...K pan head Phillips screws 2 K ...

Страница 6: ...ted in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number nameplate label The model and serial number label is located behind the front panel on the flange below the control panel area Specific electrical requirements are listed in the chart below Follow the requirements for the type of ...

Страница 7: ...quipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button w...

Страница 8: ......

Страница 9: ...and then bottom of right hand curtain housing in top and bottom curtain channels on air conditioner Top view Bottom view 3 Extend right hand curtain outward so you may insert the first screw through the middle hole of the curtain Using 10 x pan head Phillips screw screw curtain to middle hole in air conditioner cabinet NOTE This screw is required to correctly attach curtain top to bottom to the ai...

Страница 10: ...7 ...

Страница 11: ...1 2 ...

Страница 12: ...t and 7 10 x 1 wood screws not provided to attach cabinet to frame NOTE Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and air conditioner 8 Caulk all outside wall openings around cabinet 4 Use a level to check that cabinet is level side to side CompleteInstallation NOTE Handle air conditioner carefully and gently 1 Make sure the free end of the groun...

Страница 13: ...and 2 9 5X 3 8 pan head Phillips screws attach front of panel to chassis ...

Страница 14: ...us or minus button to change the delay time from 1 to 24 hours 3 Press TIMER or wait 10 seconds Indicator light will remain on To set the Timer delay for a 1 to 24 hour delay until the air conditioner turns on keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light will flash 3 Press the plus or minus button to change the delay time from 1 to 24 hours 4 Press TIMER or wa...

Страница 15: ...ol panel will flash 2 Press the plus or minus button to change the delay time from 1 to 24 hours 3 Press TIMER again or wait 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light on air conditioner control panel will flash 3 Press the plus or minus button ...

Страница 16: ...on after turning the unit off Wait at least 3 minutes after turning the unit off before trying to restart the air conditioner Cleaningthe FrontPanel 1 Turn off air conditioner 2 Remove the air filter and clean it separately See Cleaning the Air Filter 3 Wipe the front panel with a soft damp cloth 4 Air dry front panel completely Repairing Paint Damage Check once or twice a year for paint damage Th...

Страница 17: ...liances during the hottest part of the day The louvers are blocked Install the air conditioner in a location where the louvers are free from curtains blinds furniture etc The outside temperature is below 65 F 18 C Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 65 F 18 C The temperature of the room you are trying to cool is extremely hot Allow e...

Страница 18: ...ics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by war government restrictions or restraints strikes material shortages beyond the control of FRIEDRICH or acts of God OBTAINING WARRANTY PERFORMANCE Service will be provided by the FRIEDRICH Aut...

Страница 19: ......

Страница 20: ...66129903813 1 800 541 6645 ...