42
If when the system is disarmed the ‘ALARM MEM’ LED
is flashing and the panel beeps every 10 seconds, this
indicates that an alarm has occurred.
To stop the LED flashing and panel beeping either
a.
Press . or
b.
Inspect the Event Log to find out the cause of the
alarm
Note:
If the system is Disarmed with the Remote
Control the Siren will beep twice, (unless the warning
beeps have been disabled on the Siren).
QUICK SET
The Quick Set function fully arms the system with a 5
second exit delay:-
Press
Alternatively, pressing during the exit-delay period
of any armed mode (including Part-Arm 1 and Part-
Arm 2) will reset the remaining exit-delay period to 5
seconds.
OMIT ZONE
To temporarily omit a zone and disable it during the
next armed session:-
Press
Scroll through the menu to select the required zone.
The current zone setting will be displayed.
To change the setting press .
Press to omit the zone, (i.e. zone omit = ON).
Press to re-enable the zone, (i.e. zone omit =
OFF).
After configuring the zones to be omitted as required,
press to return to Standby mode.
Note:
Omitting a zone will only affect the next armed
session. When the system is disarmed the omitted
zones will automatically be re-enabled ready for the
next armed session.
PERSONAL ATTACK (PA) ALARM
An alarm can be immediately triggered at any time
(whether the system is Armed or Disarmed) in the
event of threat or danger by activating a Personal
Attack (PA) switch on either the Remote Control or the
Control Panel as follows:
a.
Slide the Personal Attack switch on the Remote
Control upwards, or
b.
Press and hold the button for approximately 3
seconds on the Control Panel.
The alarm will continue either for the alarm duration
when the system will automatically reset or until the
system is disarmed.
DEVICE TAMPER
If the battery cover of any device (except a Remote
Control) is removed or if the Siren or Control Panel are
removed from the wall then an alarm will immediately
occur (unless the system is in Test or Program modes),
even if the system is Disarmed.
The Alarm will sound until the set alarm duration time
expires or the system is Disarmed from the Remote
Control or Keypad. The ‘ALARM MEM’ LED on the
Control Panel will flash and the panel will beep every
few seconds to indicate an alarm has occurred.
Note:
The Tamper protection facility on the Siren
operates independently of the Control Panel. If
the Tamper on the Siren is activated this will not be
indicated at the Control Panel.
CHIME
The Chime facility can only be operated with the
system in Standby mode.
Press to toggle the Chime facility between ON
and OFF.
EVENT LOG
The Event Log will store the time, date and event type
of the last 50 system ‘events’.
A new system event will be indicated by the ‘ALARM
MEM’ LED flashing and the panel beeping every 10
seconds.
To cancel the LED and stop the beeping you must
access the Event Log or press .
User Access Code
,
,
User Access Code
,
,