General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid if the product is used
in the manner intended and in accordance
with the instructions.
Application area
Portier air curtains are intended for
stationary/permanent installation above
entrances and smaller doors with a height up
to 2.5 meter. Protection class: IP21
Operation
The air is drawn in at the top of the unit and
blown out at high velocity across the doorway,
providing a protective air shield. The air
shield minimises cold draughts and reduces
heat loss through open doorways. For best
efficiency, the air curtain(s) should cover the
whole width of the opening.
Mounting
The units may only be installed horizontally
over a doorway with the air-stream directed
downwards. For the protection of wider
doorways, several units can be mounted next
to each other. For optimal performance it is
recommended that a minimum gap of 80 mm
is maintained above the air-curtain.
The total distance between PS and the wall,
and to the ceiling must be at least 120 mm.
See fig. B.
The PS is mounted using the four pcs of
threaded M6 holes on top of the unit.
The PS can be suspended using wires/chains
connected to the lifting loops included. See
fig. A.
It´s also possible to use threaded bars (M6)
connected directly to the threaded holes on
top of the unit. See fig C.
Electrical installation
The air curtain(s) should only be wired by
a competent electrician, and in accordance
with the latest edition of IEE wiring
regulations.
Different combinations of fan speed and
heat output are available. See wiring diagrams
fig. F - I.
To open the PS unit, loosen the 5 screws
positioned cloesest to the inlet grille and
remove the front by lifting it straight out/
downwards. See fig E.
On top of the unit there are knockouts
(2xØ23mm, 2xØ29mm) for routing of
electrical supply and remote switching cables.
The cable-glands used must guarantee the
protection class requirements!
Typ
Output
kW
Voltage
V
Min. cable
area
mm²
All control
230V~
0.75
PS210E03**
3
230V~ / 400V 3N~
2.5 / 1.5
PS210E06*
6
230V 3~ / 400V
3N~
2.5 / 1.5
PS210E09*
9
230V 3~ / 400V
3N~
6 / 2.5
PS215E09*
9
230V 3~ / 400V
3N~
6 / 2.5
PS215E14*
13.5
230V 3~ / 400V
3N~
10 / 4
PS210A
0
230V~
0.75
PS215A
0
230V~
0.75
To convert the elements for PS210E06-9 and
PS215E09-14 see wiring diagram fig. O.
No converion has to be done for PS210E03.
The convert sockets are located behind the
left end cap and are easily accessible after
taking off the front panel
The power and voltage could be supplied
in different connection areas (see wiring
diagram fig. J - N). In the distribution board it
is to be indicated that ”the air curtains can be
supplied from more than one connection”.
*Commutable units can be used for 3x230V or
3x400V.
**Commutable units can be used for 230V or
3x400V.
Содержание Portier PS210A
Страница 1: ...Portier 10 SE 13 GB 16 FR 19 RU...
Страница 2: ...Portier 2 PS210 1020 PS215 1530 PS210 816 PS215 1335 291 138 280 M6 4x K O 29 K O 23 111 96 100...
Страница 4: ...Portier 4 Fig F PS210 215E...
Страница 5: ...Portier 5 Fig G PS210 215E...
Страница 6: ...Portier 6 Fig H CB20 PS210 215A PS210A PS215A 230V 11 14 12 L N DC DC MDC 21 24 22 31 34 32...
Страница 7: ...Portier 7 Fig I CB20 PS210 215A PS210A PS215A...
Страница 13: ......
Страница 14: ......