Portier

9

Accessory 

Type

Control panel

CB22

Control panel

CB20

2-step Thermostat

RTI2

Door contact

MDC

Technical specifications

    

Ambient, no heat - Portier A

 

1

Technical specifications

    

Electrical heat - Portier E 

3

*

1

) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m².

*

2

t = temperature rise of passing air at maximum heat output and highest airflow.

*

3

) Alternative 400 V3~ + 230 V~ (operating supply) if the current is greater than 16 A. Applies when connecting 

several units.

Protection class: IP21. 
CE compliant.

Type

Output 
steps 
[kW]

Airflow  
 
[m

3

/h]

t*

2

 

 
[°C]

Sound 
level  
[dB(A)]*

1

Voltage  
 
[V]

Amperage  
 
[A]

Length  
 
[mm]

Weight  
 
[kg]

PS210E03 1,5/3

1200

8

50

230V~/400V3N~*

13,4/4,8

1020

17

PS210E06 3/6

1200

15

50

400V3N~*

3

9,2

1020

17

PS210E09 4,5/9

1200

23

50

400V3N~*

3

13,5

1020

17

PS215E09 4,5/9

1900

14

50

400V3N~*

3

13,5

1530

24

PS215E14 6,7/13,5 1900

21

50

400V3~

  

+ 230V~

20,0

1530

24

Type

Output 
[kW]

Airflow  
[m

3

/h]

Sound level 
[dB(A)]*

1

Voltage  
[V]

Amperage  
[A]

Length  
[mm]

Weight  
[kg]

PS210A

0

1300

54

230V~

0,45

1020

14

PS215A

0

2000

56

230V~

0,55

1530

20

Содержание Portier PS210A

Страница 1: ...Portier 10 SE 13 GB 16 FR 19 RU...

Страница 2: ...Portier 2 PS210 1020 PS215 1530 PS210 816 PS215 1335 291 138 280 M6 4x K O 29 K O 23 111 96 100...

Страница 3: ...Portier 3 Threaded bar M6 not included Wire not included Screw eye M6 Fig A Fig C B A A min 80 mm A B min 120 mm Fig B Reset Temp limiter To open T o o p e n Fig E Fig D...

Страница 4: ...Portier 4 Fig F PS210 215E...

Страница 5: ...Portier 5 Fig G PS210 215E...

Страница 6: ...Portier 6 Fig H CB20 PS210 215A PS210A PS215A 230V 11 14 12 L N DC DC MDC 21 24 22 31 34 32...

Страница 7: ...Portier 7 Fig I CB20 PS210 215A PS210A PS215A...

Страница 8: ...3N PS210E03 400V 3N 1 5 mm PS210E06 400V 3N 1 5 mm L N L1 L2 L3 230V 3 PS210E6 230V 3 2 5 mm L N L1 L2 L3 PS210E09 400V 3N 2 5 mm PS210E09 230V 3 6 mm PS215E09 400V 3N 2 5 mm PS215E09 230V 3 6 mm PS21...

Страница 9: ...upply if the current is greater than 16 A Applies when connecting several units Protection class IP21 CE compliant Type Output steps kW Airflow m3 h t 2 C Sound level dB A 1 Voltage V Amperage A Lengt...

Страница 10: ...onnected to the lifting loops included See fig A It s also possible to use threaded bars M6 connected directly to the threaded holes on top of the unit See fig C Electrical installation The air curtai...

Страница 11: ...wer supply check fuses safety cut out and time switch if any that starts and stops the unit b That the airflow selector is correctly set If the error cannot be fixed please contact qualified service t...

Страница 12: ...ionally be run for a short time when it is not being used for extended periods of time Safety For all installations of electrically heated products should a residual current circuit breaker 300 mA for...

Страница 13: ......

Страница 14: ......

Страница 15: ...20 HH S CH Main office Frico AB Tel 46 31 336 86 00 Box 102 Fax 46 31 26 28 25 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local...

Отзывы: