ELIR
6
GB
General instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference. During installation and
maintenance and when replacing the lamp
the heater should always be disconnected
from the power supply.
The element of ELIR is a halogen quartz
lamp that is operating at about 2200 ºC. The
expected lifetime of the lamp is depending
on the ambient temperature and where the
heater is installed. When it is mounted airy
and outdoor the lamp will live longer.
The guarantee is only valid if the heater
is installed and used in a way that is
described in this instruction.
Application area
This infrared heater is tested and approved
according to the EMC- and LVD regulations
and is CE compliant. Thanks to the high
protection class IP65 it is also suitable for
installation outdoors and under other damp
and wet conditions.
Normally ELIR is used to give comfort for
people in the area in front of or under the
heater, but it can also be used for drying. The
wet surface will be heated by the radiation
and the evaporation goes faster.
In winter ELIR also can be used for
defrosting purposes.
Mounting
After unpacking make sure that the appliance
is complete and shows no signs of visible
damage.
Make sure that the voltage is the same as
indicated on the rating label.
ELIR must be mounted at least 1,8 m above
the floor.
When the heater is mounted at 2 – 3 m
height on a wall the heat radiation covers
approximately an area of 2,5 x 4 m. The best
comfort is experienced when a person is
heated from two directions.
Enclosed in the package there is a wall
bracket. Make sure that the wall is firm and
that proper screws are used.
Fig. 2-4 show other mounting alternatives.
The parts needed for such installations are to
be purchased separately.
Following important notes must be followed:
- The heater should always be installed
horizontally and only by using the brackets
provided.
- The heater must not be located directly
below a wall socket.
- The minimum distances according to page
2 must be kept.
- Do not use the heater directly near a
bathtub, a shower or a swimming pool.
- The heater must be installed so that a
person standing in a shower can reach
neither the switch nor the heater.
- If installed in a bathroom the minimum
height allowed is 2,3 m in zone 1 and 2.
- The heater must not be installed in areas
where hazardous vapours may be present.
Electrical installation
The electrical installation should be
carried out by a qualified electrician and in
conformity with prevailing regulations. When
fixed an all-pole switch with at least 3 mm
breaking gap should precede the appliance.
If a cable connects the heater it should be of
type H05 RN-F 3 x 1 or similar.
N.B: The cable glands must be classified as
the heater.
Operation
- All users should be made aware of all
aspects of operation and safety mentioned
in this instruction.
- The appliance is only to be used according
to these instructions.
- Children or incompetent persons must not
use this appliance.
- Do not touch the heater with wet hands or
with bare feet.
- Avoid improper use of extension cords.
- Ensure that the heater is aiming its
warmth into the target area. After you have
loosened the screws locking the heater to
the bracket adjust the angle as shown on
page 3.
Mounting and operating instructions