5. Trouble Shooting
5.1 First check:
Trouble
Possible reason
Solution
No water supply
Valve of waterline closed
Open the Valve
No Operation
No electrical power
Check with tester
Power switch off
Switch on
UV lamp malfunction
indicator lights
Replace UV lamp
Burn out fuse
Replace fuse
Wrong settingof
humidistat or higher
humidity than setting level
Reset the humidity level of
the humidistat (set higher
level for test, then set to
proper level
Less output of mist
Water in the duct hose
Apply to declivity for the duct
hose
5.2 Solutions
Volume of mist is declining
In case of declining of mist output short after the installation
●
f the water tank is contaminated with some oil or adhesive materials
used in plumbing, the mist production will be declined. If it might be so,
switch off the power and drain the water.
Take off the top cover and clean the tank
with neutral detergent and soft sponge.
Supply the water and drain it until
the bubble of the detergent will disappear
to clean the tank.
In case of declining of mist output after long hours running
●
Check the surface of the oscillator.
If it covered by some soil, clean up the surface with soft cloth.
●
If the surface is damaged or the plating is pealed off, replace it with a
new oscillator because the life has expired.
Содержание 9124654
Страница 2: ...Page 2 9124654 Service Manual Ultra Sonic Humidifier 30001322 2021 Page intentionally left blank...
Страница 24: ...Page 24 9124654 Service Manual Ultra Sonic Humidifier 30001322 2021 6 Dimensions and Specifications...
Страница 25: ...Page 25 9124654 Service ManualUltra Sonic Humidifier 30001322 2021 7 Wiring Diagram...
Страница 26: ...Page 26 9124654 Service Manual Ultra Sonic Humidifier 30001322 2021 7 Wiring Diagram...