9124654 Service ManualUltra Sonic Humidifier 30001322 2021
4. Maintenance
ANNUAL MAINTENANCE ULTRASONIC HUMIDIFIER
Every year the UV lamp and the oscillator have to be replaced.
Follow the instructions below to change these parts.
First switch the unit off.
1. Remove the Ultrasonic humidifier from the bottom frame of the
Custom Counter.
2. Remove the top panel, the left side panel, the filter and filter holder
and remove the clear drain tubes on the front side of the humidifier.
3.
Remove the clear water supply tube and disconnect the 3 white
connectors on the inside.
Now lift the inside out of the casing.
4. Disconnect the wiring of the oscillator and remove the nuts that secure
the oscillator.
Now remove the oscillator and replace this by the new oscillator.
5. Remove the black connector on the UV lamp.
Disconnect the wiring of the UV lamp.
Slide the UV lamp outside and replace by a new UV lamp.
6. Reverse the procedure to install.