Page 15
9124654 Service ManualUltra Sonic Humidifier 30001322 2021
4. Maintenance
4.6 Strainer
Strainer must be set between the water line and the water inlet pipe to protect
the unit by eliminating the dirt or the dust.
●
Turn the knob of the strainer holder counter clockwise to remove the
knob/cap.
●
Take out the strainer from the holder and clean up if there are dirt or
dust.
●
Return the strainer to the right place and shut it by knob/cap.
CAUTION:
Close the knob/cap firmly and tightly before test running or after
maintenance and checking.
Be sure not to have water inside of the strainer holder when close the
knob/cap. Otherwise, the water pressure may twist the O-ring and it
may cause water leakage.
4.7 Ultraviolet Lamp
●
Remove the mist outlet part.
●
Drain the water from the tank. Wipe out the glass tube of the lamp with
soft cloth to clean up.
Do not shave it by the hard thing like driver or do not hit the
glass tube not to damage or break.
●
After clean up, open the water line valve and switch on the electric
power to full the water in the tank and drain off so that the tank will be
clean.
●
Reassemble the mist outlet part on the water tank.