5. Trouble Shooting
5.3 COUNTERMEASURE FOR MALFUNCTION
The unit operates automatically and gives humidification as long as the water
is supplied normally and the power at normal AC 200 V.
Should it fail even under these normal conditions, check the following points
and correct the problem.
CAUTION:
Be sure to cut off the power supply when there is a need to
lift the unit or dismantle it.
●
Poor Spray
Trouble
Possible reason
Solution
Oscillator failure
Deterioration with age
Replace
Pool of water building up
in duct hose
No slope provided
Give the hose some
incline
Overflow
Dirt caught in the solenoid
valve
Dismantle the valve and
clean
●
No spray output at all
Trouble
Possible reason
Solution
No water in water tank
Faulty solenoid valve
Replace
Float switch failure
Replace
Poor connection of the
connector
Repair
Water in tank, but still no
spray output
Faulty transformer
Repair
Ultrasonic unit
Repair
PCB failure
Repair
Fan failure
Repair
Float switch failure
Repair
Poor conections of
connectors/soldered parts
Check with tester and
repair faulty connections
Содержание 9124654
Страница 2: ...Page 2 9124654 Service Manual Ultra Sonic Humidifier 30001322 2021 Page intentionally left blank...
Страница 24: ...Page 24 9124654 Service Manual Ultra Sonic Humidifier 30001322 2021 6 Dimensions and Specifications...
Страница 25: ...Page 25 9124654 Service ManualUltra Sonic Humidifier 30001322 2021 7 Wiring Diagram...
Страница 26: ...Page 26 9124654 Service Manual Ultra Sonic Humidifier 30001322 2021 7 Wiring Diagram...