background image

 

 

 

 

999076

 

– Revision A 

 

P a g e

 | 

7 of 28

 

 

 

The Freeway Height Adjustable Shower Trolley, is not a toy. Do not use it for unsafe practices. Do not allow children to 

play with the Shower Trolley or any of its components. 

 

 

Your guarantee is void if persons unauthorized by Prism Medical UK perform work on the Shower Trolley. 

 

 

To maintain optimum function, the Freeway Height Adjustable Shower Trolley should be inspected and maintained on a 

regular basis. See section ‘General Inspection, Maintenance and Cleaning’ within this user manual. 

 

 

The Freeway Height Adjustable Shower Trolley is only intended for bathing a person, and short distance transfer to the 

bathing facilities. Prism Medical UK will not be responsible for any damage caused by the misuse, neglect or purposeful 

destruction of the Unit, and/or its associated components. 

 

 

The Shower Trolley and its associated parts are certified to a maximum load of 200kg. Do not exceed the maximum 

rated load of any of the components. 

 

 

Ensure that a clear space is maintained around the Shower Trolley. Before performing a transfer, check for and move all 

obstacles out of the way. 

 

 

In areas where children are prone to be present be vigilant when carrying out a transfer.  

 

 

When the Shower Trolley is not in use, apply the castor brakes to prevent unwanted lateral movement.  

 

You may need to seek specialist advice on how to assist some people with specific bathing needs. Sources of advice 

include, but is not limited to, professional bodies and organisations, occupational therapist, physiotherapists, 

manual handling advisers and ergonomist with experience in health and social care. 

1.7

 

Warning Notes 

Your Freeway Height Adjustable Shower Trolley has been manufactured and tested to exceed BS EN 12182:2012

  

This does not mean that it can be used without care. ALL OPERATORS should have read the operating instructions 

and appreciate this warning section. 

 

1.

 

ALL Shower Trolleys are less stable on sloping surfaces. A 5-degree slope is the maximum permitted angle of intended 

use, this is relevant to both Transfer and Non Transfer Positions.  

2.

 

ALL Shower Trolleys are dangerous to the person being transferred when used recklessly or pushed at speed. 

3.

 

Surface temperatures can increase or decrease if exposed to external sources of heat or cold – This could be direct 

sunlight coming through the window over a duration of time.  

1.8

 

Operating Environment

 

The Freeway Height Adjustable Shower Trolley is intended for use within the professional health care facility environment as 

well as the home health care environment. The Shower Trolley is not suitable for any other environment or special 

environments.  

 

The Shower Trolley is not intended to be used in environments where there are rapid changes in the environmental 

temperature and humidity during intended use. 

Содержание Height Adjustable Shower Trolley with Liner 1500mm

Страница 1: ...18 03 21 Height Adjustable Shower Trolley User Manual This document includes the following models Height Adjustable Shower Trolley with Liner 1500mm Height Adjustable Shower Trolley with Liner 1700mm...

Страница 2: ...10 3 3 1 Liner and Drainage Pipe 10 3 3 2 Head Rail and Foot Rail 11 3 3 3 Final Assembly 11 Operating instructions 12 4 1 Manoeuvring the Shower Trolley 12 4 2 Brakes 12 4 3 Head Rail and Foot Rail 1...

Страница 3: ...f 28 Disposal 17 Fault Finding 18 General Inspection Maintenance and Cleaning 19 9 1 Service 19 9 2 Inspection 19 9 3 Cleaning 20 9 3 1 General cleaning 20 9 3 2 Disinfecting if necessary 20 Warranty...

Страница 4: ...without prior written notice If during the use of this device or as a result of its use a serious incident has occurred please report it to the manufacturer and to your national authority Do not attem...

Страница 5: ...ons before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date of manufacture Serial number Pa...

Страница 6: ...on the dignity and wellbeing of the person being moved the simple to use trolley maximises the amount of care provided to the person The Shower Trolley has the option of height adjustments allowing a...

Страница 7: ...ement You may need to seek specialist advice on how to assist some people with specific bathing needs Sources of advice include but is not limited to professional bodies and organisations occupational...

Страница 8: ...ived all the components contact Prism Medical UK dealer immediately contact details are provided on the last page of this manual Item Description Item Description 1 Support Frame 8 Drainage Pipe with...

Страница 9: ...he Shower Trolley The environment in which the Shower Trolley is situated in whilst carrying out a transfer is required to be on a flat surface with no steep inclines 3 2 Unboxing Shower Trolley When...

Страница 10: ...ockwise until it is secure and tight See Figure 6 Ensure the threaded pipe fixing is secured tight to avoid inadvertent detachment E Attach the pipe by rotating the thread anticlockwise until it is se...

Страница 11: ...igure 9 B Slide the Head Foot Rail into the slots ensure the rail is correctly orientated with the rail facing upward as shown in figure 10 C Tighten the Star Handles to secure the Rails The rail posi...

Страница 12: ...2 Brakes A The Freeway Height Adjustable Shower Trolley has four braked castors B The castors should can be applied when parking adjusting the Trolley height avoiding lateral movement using to rotate...

Страница 13: ...m height it will be noticeable that the lever operation no longer decreases the height 4 5 Side Rails The Side Rails ensure the patient does not fall from the mattress support the side rails are also...

Страница 14: ...076 Revision A P a g e 14 of 28 Technical Specification 5 1 Freeway Height Adjustable Shower Trolley Dimensions Below are the dimensions of the 1900mm Adjustable Height Shower Trolley Figure 22 Figure...

Страница 15: ...r Trolleys included in this Manual Description Min Height Max Height Inside Length Min Overall Length Max Overall Length Inside Width Overall Width A B min B max AH Shower Trolley 1500mm 860 1185 1500...

Страница 16: ...l Forces Moving Force with 200 kg 115N Moving Force with 0 kg 28N Operation of the Brake 107N Operation of the Foot Lever with 0 kg 75N Operation of the Foot Lever with 200kg 267N 5 3 Expected Product...

Страница 17: ...r perform to its intended use safely the Shower Trolley must be decommissioned by an approved Service Engineer The following specifies the importance of correct disposal procedure including local laws...

Страница 18: ...or any tears or holes Castors are not operating as intended Ensure the Brake has been fully disengaged Inspect the Castors for clear deformation which is affecting its function Ensure the Castors are...

Страница 19: ...pare Parts Manual Document Number 992076 The Service must be completed every 6 months after installation of the Shower Trolley to ensure the trolley is safe for use The Freeway Height Adjustable Showe...

Страница 20: ...ed seek a replacement Plug Ensure the Plug is either fitted or available when required Foot Lever Ensure the Foot Lever is functioning as intended and safe to use prior to raising the patients height...

Страница 21: ...d contact time The device can withstand a longer contact period but the 5 minute recommendation as a minimum must be followed to provide an effective cleaning regime Blood spills should be dealt with...

Страница 22: ...ease follow the link below http www nhsggc org uk media 236215 msds actichlor plus pdf Warranty This guarantee does not affect or in any way limit your Statutory Rights 1 Prism Medical UK guarantees t...

Страница 23: ...999076 Revision A P a g e 23 of 28 Service Record History Complete this section after each service repair inspection and or maintenance...

Страница 24: ...999076 Revision A P a g e 24 of 28...

Страница 25: ...999076 Revision A P a g e 25 of 28...

Страница 26: ...999076 Revision A P a g e 26 of 28...

Страница 27: ...999076 Revision A P a g e 27 of 28 User notes...

Страница 28: ...K for any errors or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Prism Medic...

Отзывы: