background image

 

 

 

 

999076

 

– Revision A 

 

P a g e

 | 

6 of 28

 

 

1.5

 

Contraindications / Limitations

 

There are no known “contraindications” associated with the usage of the Freeway Height Adjustable Shower Trolley, provided 

they are used as per manufacturer’s recommendations and guidelines. However, it is recommended that a client specific 

assessment is completed by a trained and knowledgeable health care professional to determine the method of transfer. 

 

Prism Medical UK does not recommend a required number of care givers for the use of our products. This information and 

recommendation can only be provided after a thorough personalized, case specific assessment, as there are many factors that 

can influence these decisions. 

1.6

 

Intended Use

 

For internal use only. 

 

 

With a safe working load of 200kg, the Freeway Adjustable Height Shower Trolley is an easy to manoeuvre and easy to use 

hygiene solutions for caregivers and immobile patients. The Shower Trolleys assist patients to transfer from a bed to the shower 

and back again, as the Trolley is designed for shower room environments. The Trolley provides a safe process which involves no 

manual lifting. The Shower Trolley provides access to showering facilities for those with limited mobility, reducing risk of injury 

to the patient and caregiver. The Shower Trolley will provide complete safety, dignity and comfort to the person being 

transferred.  

 

The easy to use trolley is designed to be operated by both professional health care workers and home health care workers who 

may not have a specific range of skills in health care. Typical home care users may include, but is not limited to, teachers, 

medics, paramedics, carers, family and friends. Focusing on the dignity and wellbeing of the person being moved, the simple to 

use trolley maximises the amount of care provided to the person.  

 

The Shower Trolley has the option of height adjustments, allowing a height range of 600mm to 925mm. This allows the caregiver 

and patient the ability to choose their favoured height which will assist the caregiver to work in the safest possible position 

which will reduce the risk of injury to themselves and the patient. 

 

The device is used under instruction, and the operation of the aid is undertaken by a trained carer. 

A risk assessment must be performed before using the Shower Trolley, to ensure safe use can be established. 

 

 

The Freeway Height Adjustable Shower Trolley is intended to support a recumbent patient for bathing, showering 

and/or changing 

 

 

The Shower Trolley is indicated for use by anyone requiring bathing, showering and/or changing due to disability or 

injury, but the user must be within the specified weight limit of 200kg.  

 

 

The Freeway Height Adjustable Shower Trolley is intended to be installed on a flat and levelled surface prior to use.  

 

 

The Shower Trolley must be installed only by persons authorized by Prism Medical UK or who have the rights to install 

and commission the Shower Trolley safe for use. 

 

 

Under no circumstance should the Freeway Height Adjustable Shower Trolley or entire system be put in control of a 

person who has not been properly trained in the use and care of this equipment. Failure to adhere to this warning may 

result in serious injury to the operator, and / or the individual being transferred. 

 

 

In facilities where more than one operator will be responsible for using the Shower Trolley, it is imperative that all such 

members be trained to use the Freeway Height Adjustable Shower Trolley. A training program should be established by 

the facility to acquaint new operators with this equipment. 

 

Содержание Height Adjustable Shower Trolley with Liner 1500mm

Страница 1: ...18 03 21 Height Adjustable Shower Trolley User Manual This document includes the following models Height Adjustable Shower Trolley with Liner 1500mm Height Adjustable Shower Trolley with Liner 1700mm...

Страница 2: ...10 3 3 1 Liner and Drainage Pipe 10 3 3 2 Head Rail and Foot Rail 11 3 3 3 Final Assembly 11 Operating instructions 12 4 1 Manoeuvring the Shower Trolley 12 4 2 Brakes 12 4 3 Head Rail and Foot Rail 1...

Страница 3: ...f 28 Disposal 17 Fault Finding 18 General Inspection Maintenance and Cleaning 19 9 1 Service 19 9 2 Inspection 19 9 3 Cleaning 20 9 3 1 General cleaning 20 9 3 2 Disinfecting if necessary 20 Warranty...

Страница 4: ...without prior written notice If during the use of this device or as a result of its use a serious incident has occurred please report it to the manufacturer and to your national authority Do not attem...

Страница 5: ...ons before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date of manufacture Serial number Pa...

Страница 6: ...on the dignity and wellbeing of the person being moved the simple to use trolley maximises the amount of care provided to the person The Shower Trolley has the option of height adjustments allowing a...

Страница 7: ...ement You may need to seek specialist advice on how to assist some people with specific bathing needs Sources of advice include but is not limited to professional bodies and organisations occupational...

Страница 8: ...ived all the components contact Prism Medical UK dealer immediately contact details are provided on the last page of this manual Item Description Item Description 1 Support Frame 8 Drainage Pipe with...

Страница 9: ...he Shower Trolley The environment in which the Shower Trolley is situated in whilst carrying out a transfer is required to be on a flat surface with no steep inclines 3 2 Unboxing Shower Trolley When...

Страница 10: ...ockwise until it is secure and tight See Figure 6 Ensure the threaded pipe fixing is secured tight to avoid inadvertent detachment E Attach the pipe by rotating the thread anticlockwise until it is se...

Страница 11: ...igure 9 B Slide the Head Foot Rail into the slots ensure the rail is correctly orientated with the rail facing upward as shown in figure 10 C Tighten the Star Handles to secure the Rails The rail posi...

Страница 12: ...2 Brakes A The Freeway Height Adjustable Shower Trolley has four braked castors B The castors should can be applied when parking adjusting the Trolley height avoiding lateral movement using to rotate...

Страница 13: ...m height it will be noticeable that the lever operation no longer decreases the height 4 5 Side Rails The Side Rails ensure the patient does not fall from the mattress support the side rails are also...

Страница 14: ...076 Revision A P a g e 14 of 28 Technical Specification 5 1 Freeway Height Adjustable Shower Trolley Dimensions Below are the dimensions of the 1900mm Adjustable Height Shower Trolley Figure 22 Figure...

Страница 15: ...r Trolleys included in this Manual Description Min Height Max Height Inside Length Min Overall Length Max Overall Length Inside Width Overall Width A B min B max AH Shower Trolley 1500mm 860 1185 1500...

Страница 16: ...l Forces Moving Force with 200 kg 115N Moving Force with 0 kg 28N Operation of the Brake 107N Operation of the Foot Lever with 0 kg 75N Operation of the Foot Lever with 200kg 267N 5 3 Expected Product...

Страница 17: ...r perform to its intended use safely the Shower Trolley must be decommissioned by an approved Service Engineer The following specifies the importance of correct disposal procedure including local laws...

Страница 18: ...or any tears or holes Castors are not operating as intended Ensure the Brake has been fully disengaged Inspect the Castors for clear deformation which is affecting its function Ensure the Castors are...

Страница 19: ...pare Parts Manual Document Number 992076 The Service must be completed every 6 months after installation of the Shower Trolley to ensure the trolley is safe for use The Freeway Height Adjustable Showe...

Страница 20: ...ed seek a replacement Plug Ensure the Plug is either fitted or available when required Foot Lever Ensure the Foot Lever is functioning as intended and safe to use prior to raising the patients height...

Страница 21: ...d contact time The device can withstand a longer contact period but the 5 minute recommendation as a minimum must be followed to provide an effective cleaning regime Blood spills should be dealt with...

Страница 22: ...ease follow the link below http www nhsggc org uk media 236215 msds actichlor plus pdf Warranty This guarantee does not affect or in any way limit your Statutory Rights 1 Prism Medical UK guarantees t...

Страница 23: ...999076 Revision A P a g e 23 of 28 Service Record History Complete this section after each service repair inspection and or maintenance...

Страница 24: ...999076 Revision A P a g e 24 of 28...

Страница 25: ...999076 Revision A P a g e 25 of 28...

Страница 26: ...999076 Revision A P a g e 26 of 28...

Страница 27: ...999076 Revision A P a g e 27 of 28 User notes...

Страница 28: ...K for any errors or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Prism Medic...

Отзывы: