14
Cyclone PRO User Manual
CYCLONE PRO
The MON08 Connector adopts the standard pin-out from MON08 debugging
(as used on different ICS boards) with some modifications. The general pin-
out is as follows:
PIN 1 -
NC
GND
-
PIN 2
PIN 3 -
NC
RST
-
PIN 4
PIN 5 -
NC
IRQ
-
PIN 6
PIN 7 -
NC
MON4
-
PIN 8
PIN 9 -
NC
MON5
-
PIN10
PIN11 -
NC
MON6
-
PIN12
PIN13 -
OSC
MON7
-
PIN14
PIN15 -
Vout
MON8
-
PIN16
The physical locations of the pins are displayed below:
Figure 3-9: 16-Pin MON08 Connector Pin Locations
Please note that
NC
designates that these pins are reserved for future P&E
use.
Make sure you do not connect any signal to these lines
.
The
MON4-MON8
signals are software configurable to support connections to
different HC08 devices. Depending upon the device, either the MON4 or
MON5 pin is the single-wire communications line (which usually corresponds
to PORTA0 or PORTB0). The rest of the lines are either No Connect or are
port lines which must be put to particular values upon reset. The Cyclone
PRO software lists the target processor types and their corresponding pin-
outs for user references. The software also selects the single-wire
communications line according to the target processor type. The specific
Содержание PE Micro Cyclone Pro
Страница 1: ......
Страница 36: ...30 Cyclone PRO User Manual CYCLONE PRO Figure 4 12 Configure Cyclone Set AUX Button Func...
Страница 91: ...Cyclone PRO User Manual 85 CYCLONE PRO Figure 8 28 HCS08 Connection Assistant Interface Selection...
Страница 115: ...Cyclone PRO User Manual 109 CYCLONE PRO CS serial_file4 ser PS CS serial_file5 ser PS...
Страница 156: ...150 Cyclone PRO User Manual CYCLONE PRO...
Страница 157: ......