Cyclone PRO User Manual
127
CYCLONE PRO
13.18
68HC908JL
Figure 13-18: 68HC908JL Family MON08 Pinout
The target GND is connected to the Pin 2 of the target MON08 Header.
The target RESET line is directly connected to the Pin 4 of the target MON08
Header.
The target IRQ line is directly connected to the Pin 6 of the target MON08
Header.
PORTB0 from the target processor is connected to the target MON08 Header
Pin 10, acting as the communications line. The Cyclone PRO pulls up this
signal with a 10K Ohm resistor to the target VDD.
PORTB1, PORTB2 and PORTB3 are used for entering monitor mode. By
default the user may directly bring these signals out to the target MON08
Header.
Alternatively, the user may pull up PORTB1 and pull down PORTB2, and pull
up/down PORTB3 for clock division. In which case the user does not need to
connect these signals to the target MON08 Header.
Содержание PE Micro Cyclone Pro
Страница 1: ......
Страница 36: ...30 Cyclone PRO User Manual CYCLONE PRO Figure 4 12 Configure Cyclone Set AUX Button Func...
Страница 91: ...Cyclone PRO User Manual 85 CYCLONE PRO Figure 8 28 HCS08 Connection Assistant Interface Selection...
Страница 115: ...Cyclone PRO User Manual 109 CYCLONE PRO CS serial_file4 ser PS CS serial_file5 ser PS...
Страница 156: ...150 Cyclone PRO User Manual CYCLONE PRO...
Страница 157: ......