MPC8360E/MPC8358E PowerQUICC II Pro Processor Revision 2.x TBGA Silicon Hardware Specifications, Rev. 4
Freescale Semiconductor
53
I
2
C
Figure 34
provides the AC test load for the I
2
C.
Figure 34. I
2
C AC Test Load
Figure 35
shows the AC timing diagram for the I
2
C bus.
Figure 35. I
2
C Bus AC Timing Diagram
Data hold time:
CBUS compatible masters
I
2
C bus devices
t
I2DXKL
—
0
2
—
0.9
3
μ
s
Rise time of both SDA and SCL signals
t
I2CR
20 + 0.1 C
b
4
300
ns
Fall time of both SDA and SCL signals
t
I2CF
20 + 0.1 C
b
4
300
ns
Set-up time for STOP condition
t
I2PVKH
0.6
—
μ
s
Bus free time between a STOP and START condition
t
I2KHDX
1.3
—
μ
s
Noise margin at the LOW level for each connected device (including
hysteresis)
V
NL
0.1
×
OV
DD
—
V
Noise margin at the HIGH level for each connected device (including
hysteresis)
V
NH
0.2
×
OV
DD
—
V
Notes:
1. The symbols used for timing specifications follow the pattern of t
(first two letters of functional block)(signal)(state)(reference)(state)
for
inputs and t
(first two letters of functional block)(reference)(state)(signal)(state)
for outputs. For example, t
I2DVKH
symbolizes I
2
C timing (I2)
with respect to the time data input signals (D) reach the valid state (V) relative to the t
I2C
clock reference (K) going to the high
(H) state or setup time. Also, t
I2SXKL
symbolizes I
2
C timing (I2) for the time that the data with respect to the start condition
(S) went invalid (X) relative to the t
I2C
clock reference (K) going to the low (L) state or hold time. Also, t
I2PVKH
symbolizes I
2
C
timing (I2) for the time that the data with respect to the stop condition (P) reaching the valid state (V) relative to the t
I2C
clock
reference (K) going to the high (H) state or setup time. For rise and fall times, the latter convention is used with the appropriate
letter: R (rise) or F (fall).
2. The device provides a hold time of at least 300 ns for the SDA signal (referred to the V
IH
min of the SCL signal) to bridge the
undefined region of the falling edge of SCL.
3. The maximum t
I2DVKH
has only to be met if the device does not stretch the LOW period (t
I2CL
) of the SCL signal.
4. C
B
= capacitance of one bus line in pF.
Table 45. I
2
C AC Electrical Specifications (continued)
All values refer to V
IH
(min) and V
IL
(max) levels (see
Table 44
).
Parameter
Symbol
1
Min
Max
Unit
Output
Z
0
= 50
Ω
OV
DD
/2
R
L
= 50
Ω
Sr
S
SDA
SCL
t
I2CF
t
I2SXKL
t
I2CL
t
I2CH
t
I2DXKL
t
I2DVKH
t
I2SXKL
t
I2SVKH
t
I2KHKL
t
I2PVKH
t
I2CR
t
I2CF
P
S