Stepper Stall Detector (SSDV1) Block Description
MC9S12XHY-Family Reference Manual, Rev. 1.01
714
Freescale Semiconductor
21.4.3
Operation in Low Power Modes
The SSD block can be configured for lower MCU power consumption in three different ways.
•
Stop mode powers down the sigma-delta converter and halts clock to the modulus counter. Exit
from Stop enables the sigma-delta converter and the clock to the modulus counter but due to the
converter recovery time, the integration result should be ignored.
•
Wait mode with SSDWAI bit set powers down the sigma-delta converter and halts the clock to the
modulus counter. Exit from Wait enables the sigma-delta converter and clock to the modulus
counter but due to the converter recovery time, the integration result should be ignored.
•
Clearing SDCPU bit powers down the sigma-delta converter.
21.4.4
Stall Detection Flow
Figure 21-15
shows a flowchart and software setup for stall detection of a stepper motor. To control a
second stepper motor, the SMS bit must be toggled during the SSD initialization.