32
FPQ41 Superminor Issue 1
Problem
Cause
Solution
There is little or no
suction
(continued)
.
The lid clamps are not secure.
Check the lid clamps and tighten
them if necessary.
The filter bag is blocked.
Clean or replace the filter bag.
If the problem remains, call
Freddy Products
Swarf and debris still
remains in the filtered
coolant.
The filter used was too coarse.
Fit a filter with a smaller gauge.
Coolant or liquid is
coming out of the air
exhaust.
The tank float cut-off has not
operated.
Switch off the Superminor and
call Freddy Products.
The Superminor is
making unusual noises
and/or leaks.
Switch off the Superminor and
call Freddy Products.
If you still have a problem after following the troubleshooting guide, or if you have any
concerns, we have a team of service engineers ready to help you. We offer breakdown call-
outs, service visits and service agreements on all of our machinery.
Call
+44 (0) 1386 551944
to speak to our service team.