![Freddy Superminor Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/freddy/superminor/superminor_user-manual_2329275021.webp)
FPQ41 Superminor Issue 1
21
Make sure that the suction valve on top of the
tank turret is closed.
Figure 4-33: Suction valve closed
2.
Discharge
Select
BLOW
on the Suck/Blow valve.
Press the green
I
button of the power switch
to start the Superminor.
Figure 4-34: Select BLOW
The motor will switch on, but coolant
will only be pumped from the tank
when the discharge valve is opened.
Point the discharge nozzle to direct the
filtered coolant to the required location:
into the machine tool sump to be filtered
again through a finer filter, or to be
reused,
into a barrel to be disposed of according
to the appropriate national and local
guidelines.
Open the discharge valve to start the flow of
coolant.
Figure 4-35: Discharge valve open
Hold the discharge nozzle and valve
throughout the discharge operation,
ready to close the valve whenever
necessary. The Superminor will pulse
as the discharge nears the bottom of
the tank; this could lead to spillage if
the nozzle is not held.
Содержание Superminor
Страница 1: ...Superminor Coolant Management Vacuum User Manual...
Страница 5: ...FPQ41 Superminor Issue 1 5 1 2 EC Declaration of Conformity...
Страница 35: ...FPQ41 Superminor Issue 1 35 Figure 9 3 Superminor 110 Vac 3 kW Figure 9 4 Superminor 230 Vac 3kW...
Страница 36: ...36 FPQ41 Superminor Issue 1 Figure 9 5 Superminor 400 Vac 3 phase 3 kW...